I am running the PS5444B with 250 MHz, 12 bit, 2 channel, and acquire the maximum amount of values in one run.
The samplecount is at 134217600 per channel.
When I run my code in debug mode, everything is perfectly fine. I get everything set properly, and okay. But in Release mode only the first few million elements are valid (in one test about 9 million, in another around 8.5 million, its random how many are valid), and after that everything else is just zero.
Where does this issue come from, and what do I need to do about this? Note that in debug everything works perfectly as expected, in Release not so much.
I've been testing a modified version of the C console application using the driver and another which I have access to but am unable to reproduce the issue.
Could you please send your code to support@picotech.com and I can look through it and run some tests if necessary.