Picoscope 2204a - RC circuit - wrong RC measure

Having problems ? let us know the details here
Post Reply
Tomas
User
User
Posts: 2
Joined: Sun Dec 20, 2020 4:51 pm

Picoscope 2204a - RC circuit - wrong RC measure

Post by Tomas »

Hello,
I have a Picoscope 2204a with P6060 probes.
Trying to measure the capacitor load time in an RC circuit and getting a different value from the theory-cal one.
Tried several RC components and values.

Example: RC circuit, R=200 ohms, C=150nF, Picoscope is generating an square, 2V, 400Hz signal.
The RC should be close to 30usec and I measure 110usec.

What could it be?

Thanks

bennog
Advanced User
Advanced User
Posts: 208
Joined: Mon Nov 26, 2012 9:16 am
Location: Netherlands

Re: Picoscope 2204a - RC circuit - wrong RC measure

Post by bennog »

The sig gen has a output resistance (i think 600 ohm)
so you have actually 800 ohm and 150 nf.

for this low values of your R you need to take this into account.

Benno

Tomas
User
User
Posts: 2
Joined: Sun Dec 20, 2020 4:51 pm

Re: Picoscope 2204a - RC circuit - wrong RC measure

Post by Tomas »

Thanks Benno, that's the point.

Post Reply