Search found 656 matches

by Michael
Thu Oct 05, 2006 11:14 am
Forum: PicoScope 5
Topic: "Offset Null" does not do anything
Replies: 3
Views: 6263

Thank you Oliver,

We will investigate this for you.

Best regards,
Michael
by Michael
Wed Oct 04, 2006 8:46 am
Forum: PicoScope 5
Topic: "Offset Null" does not do anything
Replies: 3
Views: 6263

Hello Oliver,

Thank you for your post.

Can you confirm that you selected the correct channel to null and that you placed a short betweeen the input and earth?

Best regards,
michael
by Michael
Wed Oct 04, 2006 8:44 am
Forum: Pre-Sales Advice
Topic: humidity detector for 2-cell permeability
Replies: 1
Views: 4419

Hello User, You can use one of our voltage input data loggers with a potential divider to bring the voltage into the 2.5v range. The reference voltage is developed for reference. There is a very small amount of current available on this voltage output but it is not designed for driving sensors. YOu ...
by Michael
Wed Oct 04, 2006 8:41 am
Forum: Pre-Sales Advice
Topic: Solar Monitoring
Replies: 3
Views: 5946

Hello Jim,

You can use a relay to switch a NO or NC contact and use the resistance input to check for pump activation. Similarly you can switch a low voltage supply to indicate pump activation and use the voltage measurement input of the DrDAQ.

Best regards,
michael
by Michael
Mon Oct 02, 2006 10:29 am
Forum: PicoLog
Topic: DrDAQ connected to WINXP via USB Parallel Port CRASHES pico
Replies: 12
Views: 18130

Hello Robert,

Can you confirm that you are using the latest version of software(5.14.6)?

You can download the software from our website: www.picotech.com/software.html

Best regards,
Michael
by Michael
Mon Oct 02, 2006 10:24 am
Forum: PicoScope 5
Topic: power spectral density
Replies: 2
Views: 6606

Hello,

You will need to change the spectrum screen options.

Go to the settings menu and choose options. Now select Y axis and change from dB to volts RMS.

Best regards,
Michael
by Michael
Mon Oct 02, 2006 10:13 am
Forum: Pre-Sales Advice
Topic: Solar Monitoring
Replies: 3
Views: 5946

Hello Jim, THank you for your post. For this application, I would recommend the DrDAQ unit. This will allow you toi measure two temperature inputs and switch or power on/off all in one unit. http://www.drdaq.com The DrDAQ is connected and powered by the Parallel port, a USB adapter is available. Bes...
by Michael
Mon Oct 02, 2006 9:57 am
Forum: Pre-Sales Advice
Topic: Twin climate chamber
Replies: 4
Views: 7372

Hello, Thank you for your post. I would recommend you use your existing humidiprobe and add another Humidiprobe and a TC08. All this providing you can dedicate a PC for data logging throughout this test. PicoLog will support multiple different devices for this type of test. PicoLog has the ability t...
by Michael
Fri Sep 29, 2006 10:57 am
Forum: General Software Discussions
Topic: USB Parallel digitial IO
Replies: 1
Views: 4010

Helo Jal,

Our Parallel port adapter is not suitable or compatible with non-Pico products.

Best regards,
Michael
by Michael
Fri Sep 29, 2006 10:27 am
Forum: PicoLog
Topic: PicoLog - Unstable
Replies: 19
Views: 27191

Hello,

Please download and test the latest version.

Please let me know if you do find this problem again.

Best regards,
Michael
by Michael
Fri Sep 29, 2006 10:18 am
Forum: PicoLog
Topic: Calculate help !!
Replies: 1
Views: 4328

Hello, THank you for your enquiry. You will need to know the upper and lower limits of your flow meters. You can then add a graph range to accomodate this range and use a formatted value. If you require further information or help, please post your flow meter details and any other relevant informati...
by Michael
Fri Sep 29, 2006 10:07 am
Forum: PicoScope 5
Topic: PS3000 labview example
Replies: 3
Views: 6942

Hello,

Thank you Gruntman.
Please find the 3000 series LV example in full.

Best regards,
Michael
by Michael
Fri Sep 29, 2006 9:59 am
Forum: PicoScope 5
Topic: ETS mode and Auto Trigger After
Replies: 1
Views: 5383

Hello, Thank you for your post. ETS is a way of increasing the effective sampling rate when working with repetitive signals. It is controlled by the ps3000_set_trigger() and ps3000_set_ets() functions. ETS works by capturing many instances of a repetitive waveform, then combining them to produce a c...
by Michael
Fri Sep 29, 2006 9:46 am
Forum: PicoScope 5
Topic: ps3000_set_trigger function
Replies: 2
Views: 4981

Helo Feng, I hope you are doing well with your 3206. The bandwidth of the ext trigger for the 3206 150MHz, what is your trigger signal speed? When running blocks of sampling, you can change the trigger, timebase, voltages and sampling rates before each block starts. So if you have say 4 blocks with ...
by Michael
Fri Sep 29, 2006 9:25 am
Forum: Pre-Sales Advice
Topic: single thermocouple data logger - more than 8 channels
Replies: 3
Views: 6005

Hello Guest,

THank you for your post.

Our TC08 data logger can be used in conjunction with other TC08's or any other data logger. The PicoLog software supports upto 150 channels or parameters.

All the data from connected loggers will be stored in the same log file.

Best regards,
Michael