Search found 2 matches

by fastelectron
Mon Jul 02, 2018 5:50 am
Forum: PicoScope 6 for Windows
Topic: Auto-find threshold
Replies: 3
Views: 2797

Re: Auto-find threshold

Martyn, yes when for the first time I set up an SPI-decoder, thresholds are automatically chosen. But when the next day I have to use different channels for MOSI / MISO / CLK / CS ... based on the same channel-settings-file, the auto-setup does not take place. In that case I must include the display...
by fastelectron
Tue Jun 26, 2018 10:15 am
Forum: PicoScope 6 for Windows
Topic: Auto-find threshold
Replies: 3
Views: 2797

Auto-find threshold

Hi I use PicoScope6 for Win10 and do SPI-decoding. I have troubles configuring appropriate thresholds to sense the signals to be decoded or to be used as clock. The issue comes up because the offset being used for displaying the signals "stacked" interferes with the offset/value of the threshold for...