ADC-212/3

  • manuals
  • download

ADC-212

This product has now been discontinued.
Listed here are the final specifications for the ADC-212/3.

View our USB Oscilloscopes, Data Acquisition and Vehicle Diagnostics products to see our current range of PC-based test and measurement equipment.

ADC-212/3
Channels 2 x BNC + 1 external trigger
Analog bandwidth 1.5 MHz
Sampling rate 3 MS/s
Sampling rate (dual channel) 3 MS/s
Resolution 12 bit
Buffer memory 32 kS
Dynamic range 80 dB
Scope timebases 2 µs/div to 50 s/div
Spectrum ranges 0 to 1.5 MHz
Trigger modes Free run, Auto, Repeat & Single
Pre/ post trigger ±100 %
Voltage ranges ±10 mV to ±20 V in 11 ranges
Overload protection ±100 V
Input impedance 1 MΩ
Coupling AC, DC
Accuracy ±1 %
Power supply 500 mA @ 12 V (mains adaptor supplied)
Output connector D25 to PC parallel port (cable supplied)
Dimension 140 x 190 x 45 mm   (5.51 x 7.48 x 1.77 in)
Supplied software PicoScope (oscilloscope, spectrum analyser, meter), PicoLog (data logger), Software Development Kit and Linux drivers.
Software is supplied on CD and is compatible with 32-bit editions of Windows XP (SP2) and Vista.