Search found 109 matches

by matthew
Thu Jan 16, 2003 9:09 am
Forum: General Software Discussions
Topic: Acessing TC08 remotely over the internet using Visual Basic
Replies: 4
Views: 10117

Hi John, There's no reason why you couldn't do this, although we don't have any example code ourselves. I'm not sure how to do this with VB, but there are loads of resources available to help you out. This site is dedicated to doing just this: http://www.vbip.com/ Hope this helps to point you in the...
by matthew
Thu Jan 16, 2003 8:57 am
Forum: Getting Started
Topic: RedHat7_0 to 7_3
Replies: 1
Views: 5668

Hi Naoshi, The ADC-11 Linux application compiles easily on any Linux station I have tried. Perhaps there is something wrong with your compiler/OS installation. Have you tried rebooting your Linux workstation and trying insmod again? I know that the application works on Red Hat 7.2, as this is our ma...
by matthew
Wed Dec 18, 2002 12:57 pm
Forum:
Topic: bored tech - heart monitor
Replies: 3
Views: 13069

ECG Information

Thanks for the input Steve,

One of my collegues found this info which shows how to compensate for the noise signal by generating a ground plane of noise on the leg and inverting it (basically the same as steve suggests).

http://www-s.ti.com/sc/psheets/sbos051/sbos051.pdf

Best Regards,
Matt.
by matthew
Wed Dec 18, 2002 11:38 am
Forum: General Software Discussions
Topic: TC-08 and Linux
Replies: 4
Views: 35900

Hi Peter, The best answer to your first question lies in the help files tc08.hlp (located in the Start Menu | Programs | Pico Technology once you have installed the windows application) This contains information on how to convert values. The Linux driver does not have the capability to change the re...
by matthew
Wed Dec 18, 2002 11:23 am
Forum:
Topic: bored tech - heart monitor
Replies: 3
Views: 13069

Heart Monitors

Hi Alex, I'm not an expert in this area, but I believe that you would need something like the conductive gel pads that you see in hospitals (anyone ... feel free to contradict me here). I would guess that either a good degree of shielding or filtering would be required since mains frequency signals ...
by matthew
Thu Dec 12, 2002 11:15 am
Forum: Getting Started
Topic: ADC-11 not work on RedHat7_3
Replies: 1
Views: 5551

Linux software Compilation

Hi Naoshi, Sorry to hear this isn't working straight away for you. I have Linux 2.4 here and have recently compiled from the Picopar.tar ' make ' file. The application compiled without problem, and seems to be very robust. Maybe there is a problem with the compiler you have on your system? ... it wo...
by matthew
Tue Dec 10, 2002 6:00 pm
Forum: General Software Discussions
Topic: More info on adc11_set_trigger function
Replies: 3
Views: 8508

Hi Dan,

Does the ADC-11 trigger correctly in PicoScope (you hint at this but do not state it explicitly)?
Try it in Auto-Trigger mode.

Regards,
by matthew
Tue Dec 10, 2002 5:54 pm
Forum: General Software Discussions
Topic: ADC11_get_unit_info in LabView
Replies: 3
Views: 9093

Hi,

I'll have a look into this. I've not used the driver yet myself, so it may take some time to modify a program to do the testing. I will post something here when I get some results.

Kind Regards,
by matthew
Mon Dec 09, 2002 4:26 pm
Forum: PicoScope 5
Topic: modifying of the displayed values
Replies: 5
Views: 11509

Large Formatted Displays with DDE

Hi Jan, One of my colleagues came up with a good idea. You can use DDE (Dynamic Data Exchange) to display the data in a spreadsheet such as Microsoft Excel using the following cell formula: =PLW|Current!Value You can format the data in PicoLog to contain the correct number of significant figures, th...
by matthew
Fri Dec 06, 2002 4:19 pm
Forum: PicoScope 5
Topic: Pico scope glitch on laptop.
Replies: 5
Views: 11576

Strange problem this, it may be that the unit (which unit is it?) is filling up with data more quickly than you would like it to (we should be able to work around it if this is the problem). In the Settings | Options menu, click on Advanced and let me know what the ' Maximum Samples per Scope trace ...
by matthew
Fri Dec 06, 2002 3:09 pm
Forum: PicoScope 5
Topic: Servicing Cd players Clear Eye Patterns with an ADC200
Replies: 2
Views: 8068

Colour Persistance Application

I have tried this capture, but I am not convinced that I have the correct test points on the CD Player I am using. The Analogue Persistance display mode seems to work very well for this, but I am still waiting on advice from Steve as to what sort of trace he expects to see and whether or not you nee...
by matthew
Fri Dec 06, 2002 2:04 pm
Forum: PicoScope 5
Topic: Input Signal Filtering
Replies: 1
Views: 5305

The unit doesn't provide analogue filtering, but there is a certain degree of digital filtering, you can apply this from Setting | Options , change the Display Mode to: Current (filtered) . The filtering factor cannot be directly modified, it is a product of the screen resoution and the amount of da...
by matthew
Wed Dec 04, 2002 2:05 pm
Forum: PicoScope 5
Topic: Add THD+N vs Power watts for test poweramp
Replies: 1
Views: 5693

Specific Applications

Hi Virat, 1. What you are proposing here is a highly specific application for profiling the characteristics of a system with a Spectrum / FFT measurement ... because PicoScope is designed as an oscillocope (not a logger), the application you suggest isn't possible to create. 2. Because you are not u...
by matthew
Thu Nov 28, 2002 3:19 pm
Forum: Getting Started
Topic: Pico on RM Connect Networks
Replies: 1
Views: 5891

RM Connect

Hi Paul,

This isn't something we've designed the software to do, and don't really have any experience with :(.

Have you considered contacting RM they have a contact form and also a knowledge base.

Best regards,
by matthew
Thu Nov 28, 2002 2:47 pm
Forum: Pre-Sales Advice
Topic: PT100 cable
Replies: 1
Views: 10496

Extending PT100 cables

Sorry it took a while to get back to you on this Marion, I needed to discuss some safety aspects with one of our electrical engineers. The extension itself is no problem, our PT100s are 4 wire and hence are compensated for changes in cable resistances. The question arises that you may be using the P...