Re: PicoLog 6.1.18 doesn't show a chart with the data from PicoScope 2204A

Sample interval is the time between individual samples displayed on the graph, not the duration of the logging run. Try setting this to 1 second and you should see data displayed on the trace.
by Martyn
Tue Mar 16, 2021 7:24 am
Forum: PicoScope 5
Topic: is PS5xxxD the same as my PS5xxxA?
Replies: 1
Views: 817

Re: is PS5xxxD the same as my PS5xxxA?

You will find your device listed under the Discontinued Products in column 1 of the downloads,

The primary difference is that the D models are USB3, the A models are USB2.
by Martyn
Thu Mar 11, 2021 9:55 am
Forum: PicoLog
Topic: PicoLog Frequency Measurement
Replies: 2
Views: 837

Re: PicoLog Frequency Measurement

PicoLog 6 samples at only 1kSample/second maximum and does not support Frequency Measurements. The document you have linked to relates to the old PicoLog 5 software https://www.picotech.com/downloads/_lightbox/picolog-5 which will support this and works with the 1216 The alternative would be to use ...
by Martyn
Thu Mar 11, 2021 9:38 am
Forum: USB PC Oscilloscopes
Topic: Pico screen grey.
Replies: 2
Views: 844

Re: Pico screen grey.

We need some more information :-

Which device do you have ?
What software are you trying to use ?
What O/S do you have on the laptop ?
by Martyn
Wed Mar 10, 2021 8:59 pm
Forum: PicoScope 6 for Windows
Topic: Record a specific time (or number of samples) at each trigger
Replies: 3
Views: 1036

Re: Record a specific time (or number of samples) at each trigger

Rapid trigger kicks in on the faster timebase, I can't remember where the switch is but probably low usecs/div
by Martyn
Wed Mar 10, 2021 6:11 am
Forum: PicoScope 6 for Windows
Topic: Decoding CAN-FD signal
Replies: 5
Views: 1254

Re: Decoding CAN-FD signal

Thank you for the files.

Our development teams work on a two week sprint cycle and they have added this to the current one which started on Monday. I will be able to update you later in the cycle.
by Martyn
Mon Mar 08, 2021 9:50 am
Forum: Getting Started
Topic: PicoLog, PicoScope and PicoLog1216
Replies: 3
Views: 1116

Re: PicoLog, PicoScope and PicoLog1216

I was expecting you to have received a reply so I will chase up.

One point to note is that you are using an older version of PicoScope 6 6.13.15 hence the driver version differences, so it may be worth updating.
by Martyn
Fri Mar 05, 2021 10:48 am
Forum: Getting Started
Topic: PicoLog, PicoScope and PicoLog1216
Replies: 3
Views: 1116

Re: PicoLog, PicoScope and PicoLog1216

I have seen that you have emailed support@picotech.com and a colleague will be in contact shortly.
by Martyn
Thu Mar 04, 2021 2:56 pm
Forum: C and C++
Topic: PS5000A window trigger
Replies: 1
Views: 876

Re: PS5000A window trigger

Can we see your code to understand how you have called the functions. You can either post it here or send it to support@picotech.com
by Martyn
Thu Mar 04, 2021 7:12 am
Forum: PicoScope 6 for Windows
Topic: Record a specific time (or number of samples) at each trigger
Replies: 3
Views: 1036

Re: Record a specific time (or number of samples) at each trigger

Sounds like you need rapid trigger mode. Rapid trigger mode allows you to segment the PicoScope buffer memory and make acquisitions to successive segments with minimum delay between each acquisition. As the scope does not communicate with the PC between captures, this reduces the gap from millisecon...
by Martyn
Thu Mar 04, 2021 7:06 am
Forum: Applications
Topic: css script
Replies: 1
Views: 778

Re: css script

Can you explain what you would like to do in more detail.
by Martyn
Wed Mar 03, 2021 8:38 am
Forum: General Software Discussions
Topic: Documentation Error: ps5000aOpenUnit
Replies: 2
Views: 1108

Re: Documentation Error: ps5000aOpenUnit

The entry point in the driver code is

Code: Select all

PICO_STATUS PREF2 ps5000aOpenUnit(int16_t* handle, int8_t* serial, PS5000A_DEVICE_RESOLUTION resolution)
as reflected in the ps5000aApi.h header file.

For .Net string is a reference type and it behaves as a reference, so passing by value is correct.
by Martyn
Wed Mar 03, 2021 7:07 am
Forum: Applications
Topic: Meaure mains with PicoScope 2204
Replies: 2
Views: 921

Re: Meaure mains with PicoScope 2204

To measure mains with a PicoScope 2204a will require the use of an appropriate category rated differential probe or an isolation transformer. We cannot advise any other approach for this. Even with care accidents can happen. To try any other approach risks damage to the circuit being tested, the sco...
by Martyn
Tue Mar 02, 2021 2:31 pm
Forum: LabVIEW
Topic: Picoscope 2408 Driver
Replies: 12
Views: 3650

Re: Picoscope 2408 Driver

It looks like you may have PicoScope 6 open from your screenshot, if it is open and connected to the scope the LabVIEW examples will not work.
by Martyn
Tue Mar 02, 2021 2:29 pm
Forum: PicoScope 6 for Windows
Topic: Signal Generator in Picoscope 6 not working
Replies: 3
Views: 932

Re: Signal Generator in Picoscope 6 not working

Connect your probe to channel A and then put the probe tip into the SigGen BNC port (Marked AWG)