Search found 7 matches

by Ortenzi
Tue Apr 19, 2011 2:36 pm
Forum: PicoScope 6 for Windows
Topic: Setup the Picoscope to take only one wave at 1M sampling
Replies: 1
Views: 2710

Setup the Picoscope to take only one wave at 1M sampling

Hello, I need only acquire signals from an acoustic source at the sample rate of 1MHz by 300 seconds, continuously with three channels. Does the PICO4424 with the latest version of PicoScope do it? In positive case how can I set up the software? I tried to do this without success and I can't join 3 ...
by Ortenzi
Sun Jan 02, 2011 11:31 pm
Forum: PicoScope 6 for Windows
Topic: Very unsatisfied with the PICOSCOPE 4424 ...
Replies: 3
Views: 4559

Re: Very unsatisfied with the PICOSCOPE 4424 ...

I'm using the 6.4.92.0 ... So, I want know if the Picoscope 4424 is capable to take at least 60 points per second in the frequency range of 2.5 up to 650 kHz by 400 seconds without interruption using only one wave. Regarding the filter, I need the high pass. The low pass I'm using the internal from ...
by Ortenzi
Thu Dec 02, 2010 1:40 pm
Forum: PicoScope 6 for Windows
Topic: Measure phase angle?
Replies: 2
Views: 4186

Re: Measure phase angle?

Take a look at my post: I've attached a file that has some controls to take measurements. Unfortunately, doesn't works with my PICOSCOPE 4424, could be run with your ...

Very unsatisfied with the PICOSCOPE 4424 ... posted by Ortenzi.
by Ortenzi
Thu Dec 02, 2010 1:35 pm
Forum: PicoScope 6 for Windows
Topic: Very unsatisfied with the PICOSCOPE 4424 ...
Replies: 3
Views: 4559

Very unsatisfied with the PICOSCOPE 4424 ...

I don't know why some controls are disable in my picoscope 4424. The peak to peak measurement can't be adjusted to the limits I want. The frequencies can't be filtered in measurement options to show only the peaks above a specific limit. Take a look on the image file. In LABVIEW I 've used the same ...
by Ortenzi
Thu Dec 02, 2010 10:05 am
Forum: PicoScope 6 for Windows
Topic: How to filter noise frequencies ...
Replies: 1
Views: 2843

How to filter noise frequencies ...

Hello, Could someone help me to solve this issue? I'm taking signals from a test and the Universal machine has a noise of 340 ~350 Hz. It will be easy to take the phase angle directly, but I'm don't know if the software can do this because the signal acquired isn't perfectly sinusoidal. Could I filt...
by Ortenzi
Tue Nov 23, 2010 5:00 pm
Forum: PicoScope 6 for Windows
Topic: Picosoft v. 6.4.92 used with picoscope 4424
Replies: 2
Views: 3969

Re: Picosoft v. 6.4.92 used with picoscope 4424

Yes. Always. All times I tried to change something the software has blocked. I couldn't do anything because I cann't to put and save my start settings in the bwta version.
by Ortenzi
Sat Nov 20, 2010 5:06 pm
Forum: PicoScope 6 for Windows
Topic: Picosoft v. 6.4.92 used with picoscope 4424
Replies: 2
Views: 3969

Picosoft v. 6.4.92 used with picoscope 4424

Hi, I've attached a file with continously error on PICO 6.4.92 when we're trying to change something the program simply freezes. The zip file here is only of the 5 different condiction where the soft freezed. I'd try to install the beta version but I think that it worst at this time. Another questio...