Search found 16 matches

by creed
Mon Aug 01, 2022 11:52 am
Forum: Getting Started
Topic: Trigger when transmissions start or stop
Replies: 20
Views: 8079

Re: Trigger when transmissions start or stop

We have discovered the reason behind the false trigger. It is because while the longest period of zero level signaling without stopping transmissions is 180 ns, all the triggers we have tried so far trigger on either a high or low level and since the signaling could be all -1 and 0 (or all 1 and 0) ...
by creed
Thu Jul 28, 2022 8:32 pm
Forum: Getting Started
Topic: Trigger when transmissions start or stop
Replies: 20
Views: 8079

Re: Trigger when transmissions start or stop

We have discussed in-house in the past that if Window Dropout had a way to select only Entering or only Exiting (instead of the way it currently works where it is both entering or exiting) that this might help our use case.
by creed
Thu Jul 28, 2022 8:08 pm
Forum: Getting Started
Topic: Trigger when transmissions start or stop
Replies: 20
Views: 8079

Re: Trigger when transmissions start or stop

I wanted to update that we have seen the Level Dropout triggers on both start and end of transmissions rather than on only the end of transmissions as desired.
by creed
Thu Jul 28, 2022 3:11 pm
Forum: Getting Started
Topic: Trigger when transmissions start or stop
Replies: 20
Views: 8079

Re: Trigger when transmissions start or stop

The signal is not always the same length. To clarify I specifically do not want to trigger on both start and stop at the same time, these are two different asks for two different use cases we have. The largest space in the signaling that we would not want to consider a start or stop of transmitting ...
by creed
Thu Jul 28, 2022 2:41 pm
Forum: Getting Started
Topic: Trigger when transmissions start or stop
Replies: 20
Views: 8079

Re: Trigger when transmissions start or stop

We have attemted to use Pulse Width for start of transmissions, the issue we find is that it has a ton of false triggers. From the description of the trigger it seems it shouldn't so maybe this is a bug in the software. We have assumed this is a likely case as it is not consistent. Sometimes we get ...
by creed
Tue Jul 26, 2022 2:41 pm
Forum: Getting Started
Topic: Trigger when transmissions start or stop
Replies: 20
Views: 8079

Re: Trigger when transmissions start or stop

Yes, you may publish them here. The signaling is PAM3 and in theory, the longest period of 0's in normal signaling could be up to 120 ns plus a small tolerance. So anything greater than that we would consider stopping transmitting for that trigger. The starting transmitting trigger is obviously just...
by creed
Tue Jul 05, 2022 5:34 pm
Forum: Getting Started
Topic: Trigger when transmissions start or stop
Replies: 20
Views: 8079

Re: Trigger when transmissions start or stop

Please send an FTP login.
by creed
Wed Jun 29, 2022 2:29 pm
Forum: Getting Started
Topic: Trigger when transmissions start or stop
Replies: 20
Views: 8079

Re: Trigger when transmissions start or stop

I have two files one with the start of transmissions example and one with the end of transmissions example. I would like the trigger to be based on Channel B starting transmissions in the one and on Channel B stopping transmissions in the other. However, they are too large to attach here and zipping...
by creed
Mon Jun 27, 2022 10:07 am
Forum: Getting Started
Topic: Trigger when transmissions start or stop
Replies: 20
Views: 8079

Re: Trigger when transmissions start or stop

Yes as I said in my post I used our hardware that we can control a logical signal on channel A to go high at the same time that we stop transmissions (or start them) in order to show what we need to be able to trigger on. However, we need to be able to trigger on the Channel B type event in the scre...
by creed
Fri Jun 24, 2022 1:40 pm
Forum: Getting Started
Topic: Trigger when transmissions start or stop
Replies: 20
Views: 8079

Re: Trigger when transmissions start or stop

This would trigger on every edge though, which would have a bunch of triggers we don't want and can't have happening for our use case. I need it to only trigger on the types of events shown in the images. A rising or falling edge trigger would trigger millions of times before that as well as the sig...
by creed
Thu Jun 23, 2022 11:48 pm
Forum: USB PC Oscilloscopes
Topic: Trigger on transmissions stopping
Replies: 2
Views: 6334

Re: Trigger on transmissions stopping

I didn't get a notification of this response for some reason. I am attaching a pssettings file for this. The screenshot is here:
leveldropout.png
by creed
Thu Jun 23, 2022 11:35 pm
Forum: Getting Started
Topic: Trigger when transmissions start or stop
Replies: 20
Views: 8079

Trigger when transmissions start or stop

Our team has been attempting to setup triggers that reliably trigger when transmissions either start or stop on a channel. We need one trigger to fire only if transmissions start. We need a second trigger to fire only if transmissions stop. We have looked at the Trigger resources in the User Guide, ...
by creed
Fri Jun 11, 2021 11:21 pm
Forum: USB PC Oscilloscopes
Topic: Trigger on transmissions stopping
Replies: 2
Views: 6334

Trigger on transmissions stopping

I am trying to find a way to trigger when a channel's transmissions stop. But I do not want it to trigger when the channel's transmissions start again. I had thought this would be a level dropout trigger, however, this does not work as I would expect. This image was taken with the following level dr...
by creed
Tue Apr 20, 2021 9:20 pm
Forum: PicoScope 6 for Windows
Topic: Differential Manchester encoding
Replies: 7
Views: 8522

Re: Differential Manchester encoding

This would be useful for our team as well.
by creed
Tue Apr 20, 2021 8:49 pm
Forum: PicoScope 6 for Windows
Topic: How to save Zoomed area only
Replies: 2
Views: 4504

Re: How to save Zoomed area only

I am curious if there will be an update to allow this feature again. My organization would greatly benefit from this feature.