Search found 8 matches

by HPC
Mon Nov 06, 2023 7:54 am
Forum: Applications
Topic: Frequency Response Analyzer with Bode Plots
Replies: 631
Views: 3288030

Re: Frequency Response Analyzer with Bode Plots

Hi Aaron, I would like to add my thanks to Aaron. His software together with the ImpedanceViewer software from eevblog allows new insights into the behavior of e.g. inductors and capacitances, especially with the high resolution of PicoScope 5xxx. (So far I have been quite happy with my PicoScope 3x...
by HPC
Fri Oct 06, 2023 5:50 am
Forum: Applications
Topic: Frequency Response Analyzer with Bode Plots
Replies: 631
Views: 3288030

FRA4: Installation of newer version fails

Hello forum, I have installed version “0.7.0b RC1” on a Windows 10 PC and would like to update to “FRA4PicoScope_0.8.0_beta.msi”. I am asked to specify the path to the installation package “FRAPicoSope_0.7.0b_RC1.msi”. This package is not available on the download page. So unfortunately I fail. Can ...
by HPC
Mon Oct 10, 2022 12:12 pm
Forum: PicoScope 7 for Windows, Linux and Mac
Topic: PicoScope 7:
Replies: 1
Views: 1149

PicoScope 7:

Dear picoscope-team,

please forgive the question: When will version 7 have at least the same range of functions as version 6?

Best regards,

from a picoscope fan
by HPC
Mon Jun 21, 2021 5:43 am
Forum: PicoScope 7 for Windows, Linux and Mac
Topic: Problem with Symantec
Replies: 0
Views: 20179

Problem with Symantec

Hi,
I got the attached message on an windows 10 pc at my company.
by HPC
Wed Jun 16, 2021 10:58 am
Forum: PicoScope 6 for Windows
Topic: Export psdata with consideration of custom probe setting
Replies: 2
Views: 3895

Re: Export psdata with consideration of custom probe setting

Hi,
I found my mistake myself.
The text file contains the correct unit of the current that my clamp meter measured. I should have read more carefully.
by HPC
Tue Jun 15, 2021 5:24 am
Forum: PicoScope 6 for Windows
Topic: Export psdata with consideration of custom probe setting
Replies: 2
Views: 3895

Export psdata with consideration of custom probe setting

Hi, I saved my measurement as psdata file and can look again at it using picoscope 6 software. For further investigation I can export dataset als txt or csv file. But it seems, that probe setting items and probe offset correction are not taken into account. Is there a way to extract probe setting it...
by HPC
Thu Jun 11, 2020 4:36 am
Forum: PicoScope 6 for Windows
Topic: PicoScope 6403: maximum possible sampling rate
Replies: 1
Views: 3756

PicoScope 6403: maximum possible sampling rate

Hello everyone! I have a question about the maximum possible sampling rate. A PicoScope 6403 (Serial Number: AY166 / 046) with 1 GS buffer size is used. I use 4 analog channels (8 bit resolution) and record a single curve over 20 s. More than 10 MS / s cannot be set. With a recording time of 20 s an...
by HPC
Wed Jun 10, 2020 7:32 am
Forum: PicoScope 6 for Windows
Topic: PicoScope 6403: maximum possible sampling rate
Replies: 1
Views: 3636

PicoScope 6403: maximum possible sampling rate

Hello everyone! I have a question about the maximum possible sampling rate. A PicoScope 6403 (Serial Number: AY166 / 046) with 1 GS buffer size is used. I use 4 analog channels (8 bit resolution) and record a single curve over 20 s. More than 10 MS / s cannot be set. With a recording time of 20 s an...