Search found 9 matches

by vadim_klimov
Thu Feb 06, 2020 12:45 pm
Forum: .Net Languages (C#, VB.Net, .)
Topic: Disable logo box
Replies: 1
Views: 10152

Disable logo box

I have created a program for our customers where PicoScope 6402C is used. It works well, but what is very annoying is the logo box, which comes every time the Picoscope is addressed. I guess that's built into driver somehow. It appears for a short time, but customers are unsatisfied. Is it possible ...
by vadim_klimov
Tue Nov 19, 2019 3:29 pm
Forum: .Net Languages (C#, VB.Net, .)
Topic: What function is the best for getting state?
Replies: 5
Views: 13267

Re: What function is the best for getting state?

Function OpenUnit provides PICO_NOT_FOUND = (uint)0x00000003UL if the pico is already opened. How can i distinguish if the pico is already opened or there is another error on device? With the function ps6000FlashLed is the same strange thing. It works fine if the pico is connected, but for disconnec...
by vadim_klimov
Tue Nov 19, 2019 2:56 pm
Forum: .Net Languages (C#, VB.Net, .)
Topic: What function is the best for getting state?
Replies: 5
Views: 13267

Re: What function is the best for getting state?

I'm very confusing... i use the function ps6000GetUnitInfo for checking the device. If the scope is connected it's ok. But if i disconnect the scope i get the PICO_OK back with all data. The driver seems to use the last function call. Is that right?
by vadim_klimov
Thu Nov 14, 2019 8:06 am
Forum: .Net Languages (C#, VB.Net, .)
Topic: What function is the best for getting state?
Replies: 5
Views: 13267

Re: What function is the best for getting state?

i have PicoScope 6402C and i want check if the device is available. I have an application with several devices and picoscope under other. It is used from time to time but all devices need to show their status, if they are reachable at all. In most time the scope is simply waiting. For this purpose I...
by vadim_klimov
Wed Nov 13, 2019 1:14 pm
Forum: .Net Languages (C#, VB.Net, .)
Topic: What function is the best for getting state?
Replies: 5
Views: 13267

What function is the best for getting state?

I want to check periodically a scope such as keepalive function. What a function from API is the best for this goal. I only need to know the state of scope.
by vadim_klimov
Thu Nov 07, 2019 1:22 pm
Forum: USB PC Oscilloscopes
Topic: Wrong voltage dysplay
Replies: 4
Views: 3839

Re: Wrong voltage dysplay

Oh, sorry, i founded it. I must select 50 ohms dc
by vadim_klimov
Thu Nov 07, 2019 12:39 pm
Forum: USB PC Oscilloscopes
Topic: Wrong voltage dysplay
Replies: 4
Views: 3839

Re: Wrong voltage dysplay

Output impedance of the pulse generator is 50 ohms, and the input impedance of the analog oscilloscope is 50 ohms too.
by vadim_klimov
Thu Nov 07, 2019 7:55 am
Forum: USB PC Oscilloscopes
Topic: Wrong voltage dysplay
Replies: 4
Views: 3839

Wrong voltage dysplay

I 'm new here and have little knowledge of thing. I have an pulse generator and would like to measure the signals with PicoScope. I have set the voltage of signal to 1V and can see that in analog oscilloscope as well. But picoScope shows me always 2V. What could be the cause?
by vadim_klimov
Wed Nov 06, 2019 7:50 am
Forum: PicoScope 6 for Windows
Topic: Missed PicoScope.exe after restart of computer
Replies: 1
Views: 2228

Missed PicoScope.exe after restart of computer

I have very strange problem. i've install PicoScope 6 on my win 10 enterprise machine and it works fine. But after restart of computer the exe-file "PicoScope.exe" is missing. All another files are available, only the exe is missing. The working directory is ""C:\Program Files (x86)\Pico Technology\...