Search found 6 matches

by Link
Mon Sep 23, 2019 9:09 am
Forum: Getting Started
Topic: Set up condition for stopping capturing the data
Replies: 4
Views: 4202

Re: Set up condition for stopping capturing the data

Hi, Which model PicoScope do you have? Can you post image of an example waveform you want to capture? All the trigger types are listed on pages - 158 - 6.7.2.1 Advanced Triggers dialog - https://www.picotech.com/download/manuals/picoscope-6-users-guide.pdf Hi Andrew, I'm using 5244D MSO. Sorry I pr...
by Link
Thu Sep 19, 2019 2:09 am
Forum: Getting Started
Topic: Set up condition for stopping capturing the data
Replies: 4
Views: 4202

Set up condition for stopping capturing the data

Hi there, I'd like to set up the stop conditions. I don't know how many samples is needed to be captured, but I know what is the condition to stop it, such as there is no trigger within a specified time. For example, I would like to begin to capture the data when there is a rising edge, but stop it ...
by Link
Thu Jul 18, 2019 2:11 am
Forum: Getting Started
Topic: How to set sampling rate to 50MSPS with SDK
Replies: 2
Views: 2370

Re: How to set sampling rate to 50MSPS with SDK

I see. Thanks!
by Link
Thu Jul 18, 2019 2:09 am
Forum: Getting Started
Topic: Why the measured value is scaled even I don't set it on PicoScope 6
Replies: 2
Views: 2367

Re: Why the measured value is scaled even I don't set it on PicoScope 6

That's it, I didn't know I should set the probe before. Thanks a lot!
by Link
Wed Jul 17, 2019 3:05 pm
Forum: Getting Started
Topic: Why the measured value is scaled even I don't set it on PicoScope 6
Replies: 2
Views: 2367

Why the measured value is scaled even I don't set it on PicoScope 6

Hi! I'm new to PicoScope 6. I found the measured value showed on the screen is weird. The device I use is PicoTech 5244D MSO. The software is PicoTech 6. When I test an 5V output with Channel A, I found the measured value displayed on the screen is 500 mv.The screenshot is attached. I have double-ch...
by Link
Wed Jul 17, 2019 2:51 pm
Forum: Getting Started
Topic: How to set sampling rate to 50MSPS with SDK
Replies: 2
Views: 2370

How to set sampling rate to 50MSPS with SDK

Hi, I'm new to PicoTech Scope. I'd like to start with an project for sampling input signal at 50MSPS. I have checked the API Guide, and found that the notion of 'Timebases' is what I need. However, according to the guide, I can only set the Sampling Interval as 1, 2, 4, 8, 16, 32ns ..., which I can ...