Search found 2 matches

by Jan91
Fri Feb 02, 2018 11:11 am
Forum: LabVIEW
Topic: PS2206B, Trigger direction works not fine
Replies: 2
Views: 3281

Re: PS2206B, Trigger direction works not fine

Today I find out, that this happens only if the range of the trigger channel (B) is 5V.
If I change it to 10V (or any other not equal to 5V) , everything works fine.

That is a bit strange, but reproducible.

Jan
by Jan91
Fri Feb 02, 2018 8:27 am
Forum: LabVIEW
Topic: PS2206B, Trigger direction works not fine
Replies: 2
Views: 3281

PS2206B, Trigger direction works not fine

Hello, I use PS2206B with Labview and I have some problems with the trigger direction: Configuration: Channel A: Signal (20kHz) Channel B: Trigger Signal (for testing I connected it parallel to Channel A) timebase 2 (8 nsec.) / 300.000 samples trigger: Channel B / Autotrigger = 0 / Threshold = 2V / ...