Search found 13 matches

by driesdendas
Thu Sep 27, 2018 8:01 am
Forum: PicoScope 6 for Windows
Topic: Save between rulers
Replies: 1
Views: 1841

Save between rulers

Hi,

For reporting and analyses i'like to make a saving of the data between 2 rulers,
now i export data in excell and delete the non-interresting data manually.
Is there an easier way in Picoscope 6? So i don't need to use excell anymore.

Thanks,

Dries
by driesdendas
Wed Sep 13, 2017 12:58 pm
Forum: PicoScope 6 for Windows
Topic: Zooming can truncate waveform
Replies: 5
Views: 6261

Re: Zooming can truncate waveform

Hello,

I think i've the same problem but with a saved waveform. When i zoom the waveform doenst cover the whole display. Is there a solution for this? When i importe the data in excell i see every sample.

Dries
by driesdendas
Tue Sep 12, 2017 6:46 am
Forum: PicoScope 6 for Windows
Topic: EMC-mask
Replies: 2
Views: 3215

Re: EMC-mask

Solved: I imported the FFT-values in excell and personally for me it was a lot easier to make the graph.
by driesdendas
Thu Aug 31, 2017 7:49 am
Forum: PicoScope 6 for Windows
Topic: EMC-mask
Replies: 2
Views: 3215

EMC-mask

Hi, For reporting i need to add a EMC-mask (max values allowed) as in the picture in the attachement (red is mask, blue signal) I found an image on https://www.picotech.com/library/oscilloscopes/mask-limit-testing what seems to be the same but inverted, but however i don't find a way (yet) to make t...
by driesdendas
Mon Mar 20, 2017 1:02 pm
Forum: PicoScope 6 for Windows
Topic: Scaling FFT
Replies: 1
Views: 3170

Scaling FFT

Hello,

Is there a way to set the range of the X an Y- axes in values such as 0 - 50 V / 10 - 10000 Hz.
When i do it with the zoom-function it is very difficle (impossible) to have whole numbers.

Thanks,

Dries
by driesdendas
Thu Jan 07, 2016 2:58 pm
Forum: USB PC Oscilloscopes
Topic: Picoscope 3425 max. sample rate
Replies: 3
Views: 4746

Re: Picoscope 3425 max. sample rate

Hello Andrew,

Attached you'ill find the set-file.
I suppose when the scope can reach 10 MS/s (@ filelength 1s) i can multiply the filelength by 5?
So if i use a SR of 100 KS/s my file would be 100s...

Thank you!
by driesdendas
Thu Jan 07, 2016 2:46 pm
Forum: Introductions
Topic: Hello
Replies: 1
Views: 3307

Hello

Hello,

My name is Dries Dendas. I work @ the Belgian Railways, rolling stock departement.
One of my tasks is to measure the (electrical) beheavier of our trains mostly in the power converters.
Therefore i'm working with a picoscope 3425.

Dries
by driesdendas
Wed Jan 06, 2016 2:25 pm
Forum: Pre-Sales Advice
Topic: PicoScope 4824 vs PicoScope 3425
Replies: 1
Views: 3674

PicoScope 4824 vs PicoScope 3425

All, For a while we are using a PicoScope 3425, for most applications (9/10) the results are satisfiant. But we are limited with our 4 channels :-( and we do prefer galvanic isolation off the channels. So I'm wondering if Picotech has any plans to launch a 8 channel galvanic isolated scope? In fact ...
by driesdendas
Tue Jan 05, 2016 2:12 pm
Forum: USB PC Oscilloscopes
Topic: Picoscope 3425 max. sample rate
Replies: 3
Views: 4746

Picoscope 3425 max. sample rate

All, When I want to make a 2-channel measurement with the picoscope 3425 the max. sample rate is stuck at 5 MS/s. If I could believe the manual the max. sample rate should be 10 MS/s (20 MS/s with 1 channel). Is there any possibility to increase the sample rate @ 10 MS/s (2-channels)? I'm Using the ...
by driesdendas
Tue Oct 27, 2015 10:16 am
Forum: PicoScope 6 for Windows
Topic: integration (rogowski) of a waveworm
Replies: 1
Views: 3413

integration (rogowski) of a waveworm

Hi, For one of my projects i've to measure a signal from a rogowski-coil. But the output signal of the coil is not integrated. I've found the integration-function at the math-channels but i can't obtain the result i expect The formula should be: i(t) = (c) * integral(A(t) * dt) with c = contant (thi...
by driesdendas
Mon Oct 12, 2015 10:22 am
Forum: PicoScope 6 for Windows
Topic: automatic saving after full memorybuffer
Replies: 2
Views: 3868

Re: automatic saving after full memorybuffer

Thank you the answer, solution works fine!
by driesdendas
Fri Jun 26, 2015 8:42 am
Forum: PicoScope 6 for Windows
Topic: automatic saving after full memorybuffer
Replies: 2
Views: 3868

automatic saving after full memorybuffer

Hi, I'm using a picoscope 3425 and picoscope 6.10 for my measurements. Is there a possibility to save automaticly the measures after the memorybuffer is full? I've to take measurements @ 100ks/S for a day and i can not always be present to save the measurements. Thank you in advance, Kind regards, D...
by driesdendas
Wed Oct 15, 2014 11:16 am
Forum: PicoScope 6 for Windows
Topic: Serial decoding WORLDFIP protocol
Replies: 1
Views: 2746

Serial decoding WORLDFIP protocol

Hello,

We use in our applications the WORLFIP-protocol.
Is there a possibility to add a custom-protocol as Serial decoding,
in my case the WORLDFIP-protocol?

Kind regards!

Dries