Search found 5 matches

by NewMartin
Thu Nov 02, 2017 2:26 pm
Forum: MATLAB
Topic: Switch off automatic text outputs
Replies: 3
Views: 5327

Re: Switch off automatic text outputs

Hi Neil, thank you for your quick reply. Unfortunately, I get the following error code: Error using icdevice/set (line 104) The name 'displayOutput' is not an accessible property for an instance of class device objects. when inserting the line of code: PS6000Config; ps6000DeviceObj = icdevice('picot...
by NewMartin
Thu Nov 02, 2017 8:27 am
Forum: MATLAB
Topic: Switch off automatic text outputs
Replies: 3
Views: 5327

Switch off automatic text outputs

Hi, I have to run individual measurements several hundred times using a 6403D. For each single measurement I am using the rapid block mode routine, which I call in Matlab. However, this has the nasty side effect, that each time the following status reply is written in the command line: runBlock:- Co...
by NewMartin
Wed May 04, 2016 7:28 am
Forum: Pre-Sales Advice
Topic: Requirements on the computer
Replies: 2
Views: 7494

Requirements on the computer

Hi, could you please tell me, what to keep in mind when selecting a new computer for a USB3 Pico Scope for fast data acquisition. So at the end I think, a fast RAM and SSD is most crucial and then comes a quick CPU. But what role does the grapic card play, when displaying also the data? Is the onboa...
by NewMartin
Tue Apr 05, 2016 6:45 am
Forum: USB PC Oscilloscopes
Topic: Questions on USB 3.0 oscilloscopes
Replies: 3
Views: 4366

Re: Questions on USB 3.0 oscilloscopes

Thank you very much for your answer! By averaging I mean: Continuously collecting waveforms and take the average over all of them. In averaging mode, we can collect e.g. approximately 17 waveforms within 3s of measurement time when setting the horizontal axis to 500µs per div (in total: 10 times 500...
by NewMartin
Thu Mar 31, 2016 7:13 am
Forum: USB PC Oscilloscopes
Topic: Questions on USB 3.0 oscilloscopes
Replies: 3
Views: 4366

Questions on USB 3.0 oscilloscopes

Hi, we are considering to by a Pico Scope with USB 3.0 for our research group. After reading your article on the usb bottleneck most of my questions have been answered, however I am still not sure in one point, since the article seems to focus on the live visualisation of the data via USB 3.0: In ou...