Search found 13 matches

by maxsca
Mon Apr 04, 2011 10:36 pm
Forum: PicoScope 6 for Windows
Topic: Specytrum mode issue
Replies: 3
Views: 4512

Specytrum mode issue

Have just installed the last version of Picoscope and i have found that in spectrom mode measurement (THD %) the control of harmonic detector are fixed, and only the second harmonic is detected.

Max
by maxsca
Mon Nov 08, 2010 9:39 am
Forum: PicoScope 6 for Windows
Topic: Serial deconding error
Replies: 2
Views: 3933

Serial deconding error

I'm testing the serial deconding sending two byte, 0xAA and 0x55, at 9600N81 from a PC.
The deconding fail the second byte, because this byte is sent without a delay from the first and the SW don't detect correctly the start bit.

See image.
Thanks
Massimo - Italy
by maxsca
Wed Nov 03, 2010 11:13 am
Forum: PicoScope 6 for Windows
Topic: ETS problem
Replies: 7
Views: 7850

Re: ETS problem

Ok,
i'll check the solution of the problem in the new SW release !.

Thanks
Massimo - Italy
by maxsca
Tue Oct 26, 2010 3:20 pm
Forum: PicoScope 6 for Windows
Topic: ETS problem
Replies: 7
Views: 7850

Re: ETS problem

Hello,
do you have any idea about solving the problem ??

Massim - Italy
by maxsca
Fri Oct 22, 2010 9:01 am
Forum: PicoScope 6 for Windows
Topic: ETS problem
Replies: 7
Views: 7850

Re: ETS problem

Hello, i tried to disable the sin (x) function but the defect remains! I learn that even if activated the second channel B, the 1 MHz signal 1 becomes stable (see. Two_channel_without_defect.psdata), but with only active the channel A the defect is always present (see One_channel_with_defect.psdata)...
by maxsca
Wed Oct 20, 2010 10:29 am
Forum: PicoScope 6 for Windows
Topic: ETS problem
Replies: 7
Views: 7850

Re: ETS problem

Thanks for the analasys !
Others informations: the same problem occurs with a Picoscope 3224 (same software 6.4.92) and the signal applied comes from a reference generator, therefore it's jitter free.

Massimo - Italy
by maxsca
Mon Oct 18, 2010 7:38 pm
Forum: PicoScope 6 for Windows
Topic: ETS problem
Replies: 7
Views: 7850

ETS problem

I'm using the PicoScope 2204, with version 4.6.92, to take a measure of sine wave of 1.8 MHz. When i select the AUTO trigger the waveform of the signal is not stable, but the frequency mesured is correct; if I select the ETS the wave becomes stable but the frequency, and the waveform show, becomes e...
by maxsca
Fri Sep 17, 2010 2:48 pm
Forum: PicoScope 6 for Windows
Topic: new funtion
Replies: 2
Views: 4071

new funtion

Good morning,
with a only positive signal, es. 0 to 5 Volt TTL, it's possible to remove from view the negative side to expande the signal on full screen ??

Massimo - Italy
by maxsca
Fri Sep 25, 2009 3:05 pm
Forum: PicoScope 6 for Windows
Topic: Different startup settings
Replies: 1
Views: 3007

Different startup settings

Hi,

would be useful to have the ability to load different settings in order to adapt the oscilloscope to different application.
by maxsca
Sat Sep 12, 2009 8:30 pm
Forum: PicoScope 6 for Windows
Topic: Math analisys
Replies: 1
Views: 2984

Math analisys

it's possible, with the maths functions, calculate the power (W rms)produced by the measured signal on a known load?

Note: The analysis of CAN is excellent. If you could extend to other serial bus (SPI, I2C,) would be great.
by maxsca
Mon Mar 30, 2009 9:27 am
Forum: PicoScope 6 for Windows
Topic: Harmonic analysis with version 6.2.2
Replies: 1
Views: 3292

Harmonic analysis with version 6.2.2

I have a problem with the 3224 model PicoScope 6.2.2: performing the harmonic analysis of a signal at 23 Vpp at 1 KHz, i found that the measure changes according the probe attenuation: probe 1:1 amplitude measure : 23 Vpp distorsion measure : 0.7% THD probe 10:1 amplitude measure : 23 Vpp distorsion...
by maxsca
Tue Feb 17, 2009 4:07 pm
Forum: PicoScope 6 for Windows
Topic: Decode SPI communications
Replies: 0
Views: 8800

Decode SPI communications

It's possible to implement the decoding of a SPI trasmissiome reading the data and the clock with the two channels?
Massimo - Italy
by maxsca
Fri Sep 19, 2008 10:42 am
Forum: PicoScope 6 for Windows
Topic: PicoScope version R6.1.0.4
Replies: 1
Views: 3796

PicoScope version R6.1.0.4

I have the 3224 oscilloscope with the new version R6.1.0.4 with this problem: the scale of spectrum analyzer change when modify the time/division.

New feature request:
1 - set a specific harmonic for the TDH measure.
2 - oscilloscope view in X-Y mode.