Have just installed the last version of Picoscope and i have found that in spectrom mode measurement (THD %) the control of harmonic detector are fixed, and only the second harmonic is detected.
Max
Search found 13 matches
- Mon Apr 04, 2011 10:36 pm
- Forum: PicoScope 6 for Windows
- Topic: Specytrum mode issue
- Replies: 3
- Views: 1719
- Mon Nov 08, 2010 9:39 am
- Forum: PicoScope 6 for Windows
- Topic: Serial deconding error
- Replies: 2
- Views: 1456
Serial deconding error
I'm testing the serial deconding sending two byte, 0xAA and 0x55, at 9600N81 from a PC.
The deconding fail the second byte, because this byte is sent without a delay from the first and the SW don't detect correctly the start bit.
See image.
Thanks
Massimo - Italy
The deconding fail the second byte, because this byte is sent without a delay from the first and the SW don't detect correctly the start bit.
See image.
Thanks
Massimo - Italy
- Wed Nov 03, 2010 11:13 am
- Forum: PicoScope 6 for Windows
- Topic: ETS problem
- Replies: 7
- Views: 3118
Re: ETS problem
Ok,
i'll check the solution of the problem in the new SW release !.
Thanks
Massimo - Italy
i'll check the solution of the problem in the new SW release !.
Thanks
Massimo - Italy
- Tue Oct 26, 2010 3:20 pm
- Forum: PicoScope 6 for Windows
- Topic: ETS problem
- Replies: 7
- Views: 3118
Re: ETS problem
Hello,
do you have any idea about solving the problem ??
Massim - Italy
do you have any idea about solving the problem ??
Massim - Italy
- Fri Oct 22, 2010 9:01 am
- Forum: PicoScope 6 for Windows
- Topic: ETS problem
- Replies: 7
- Views: 3118
Re: ETS problem
Hello, i tried to disable the sin (x) function but the defect remains! I learn that even if activated the second channel B, the 1 MHz signal 1 becomes stable (see. Two_channel_without_defect.psdata), but with only active the channel A the defect is always present (see One_channel_with_defect.psdata)...
- Wed Oct 20, 2010 10:29 am
- Forum: PicoScope 6 for Windows
- Topic: ETS problem
- Replies: 7
- Views: 3118
Re: ETS problem
Thanks for the analasys !
Others informations: the same problem occurs with a Picoscope 3224 (same software 6.4.92) and the signal applied comes from a reference generator, therefore it's jitter free.
Massimo - Italy
Others informations: the same problem occurs with a Picoscope 3224 (same software 6.4.92) and the signal applied comes from a reference generator, therefore it's jitter free.
Massimo - Italy
- Mon Oct 18, 2010 7:38 pm
- Forum: PicoScope 6 for Windows
- Topic: ETS problem
- Replies: 7
- Views: 3118
ETS problem
I'm using the PicoScope 2204, with version 4.6.92, to take a measure of sine wave of 1.8 MHz. When i select the AUTO trigger the waveform of the signal is not stable, but the frequency mesured is correct; if I select the ETS the wave becomes stable but the frequency, and the waveform show, becomes e...
- Fri Sep 17, 2010 2:48 pm
- Forum: PicoScope 6 for Windows
- Topic: new funtion
- Replies: 2
- Views: 1360
new funtion
Good morning,
with a only positive signal, es. 0 to 5 Volt TTL, it's possible to remove from view the negative side to expande the signal on full screen ??
Massimo - Italy
with a only positive signal, es. 0 to 5 Volt TTL, it's possible to remove from view the negative side to expande the signal on full screen ??
Massimo - Italy
- Fri Sep 25, 2009 3:05 pm
- Forum: PicoScope 6 for Windows
- Topic: Different startup settings
- Replies: 1
- Views: 1106
Different startup settings
Hi,
would be useful to have the ability to load different settings in order to adapt the oscilloscope to different application.
would be useful to have the ability to load different settings in order to adapt the oscilloscope to different application.
- Sat Sep 12, 2009 8:30 pm
- Forum: PicoScope 6 for Windows
- Topic: Math analisys
- Replies: 1
- Views: 1173
Math analisys
it's possible, with the maths functions, calculate the power (W rms)produced by the measured signal on a known load?
Note: The analysis of CAN is excellent. If you could extend to other serial bus (SPI, I2C,) would be great.
Note: The analysis of CAN is excellent. If you could extend to other serial bus (SPI, I2C,) would be great.
- Mon Mar 30, 2009 9:27 am
- Forum: PicoScope 6 for Windows
- Topic: Harmonic analysis with version 6.2.2
- Replies: 1
- Views: 1514
Harmonic analysis with version 6.2.2
I have a problem with the 3224 model PicoScope 6.2.2: performing the harmonic analysis of a signal at 23 Vpp at 1 KHz, i found that the measure changes according the probe attenuation: probe 1:1 amplitude measure : 23 Vpp distorsion measure : 0.7% THD probe 10:1 amplitude measure : 23 Vpp distorsion...
- Tue Feb 17, 2009 4:07 pm
- Forum: PicoScope 6 for Windows
- Topic: Decode SPI communications
- Replies: 0
- Views: 1828
Decode SPI communications
It's possible to implement the decoding of a SPI trasmissiome reading the data and the clock with the two channels?
Massimo - Italy
Massimo - Italy
- Fri Sep 19, 2008 10:42 am
- Forum: PicoScope 6 for Windows
- Topic: PicoScope version R6.1.0.4
- Replies: 1
- Views: 1913
PicoScope version R6.1.0.4
I have the 3224 oscilloscope with the new version R6.1.0.4 with this problem: the scale of spectrum analyzer change when modify the time/division.
New feature request:
1 - set a specific harmonic for the TDH measure.
2 - oscilloscope view in X-Y mode.
New feature request:
1 - set a specific harmonic for the TDH measure.
2 - oscilloscope view in X-Y mode.