Search found 4 matches

by Vojtech
Fri Nov 07, 2014 10:17 am
Forum: PicoScope 6 for Windows
Topic: 4227 - LIN Logic Analysis
Replies: 5
Views: 5604

Re: 4227 - LIN Logic Analysis

Hi Hitesh, Don't understand, what you mean with psdata (does psdata = print screen data?). The pictures can be downloaded from the forum, but sure, I can send them to the email you gave me. In case its some PicoScope format, just let me know please, I'll aquire the data once more. Regarding the manu...
by Vojtech
Wed Nov 05, 2014 8:32 am
Forum: PicoScope 6 for Windows
Topic: 4227 - LIN Logic Analysis
Replies: 5
Views: 5604

Re: 4227 - LIN Logic Analysis

Hi Hitesh, sorry for my late response, I was out of office without access to me equipment. Attached are two pictures captured during transmission of a LIN header from master and a response from Slave. The Sync Break is 13 bits long, the ID is 0x23 => PID is 0xA3. The response from Slave should be al...
by Vojtech
Thu Oct 30, 2014 7:06 am
Forum: PicoScope 6 for Windows
Topic: LIN decoding not reliable
Replies: 21
Views: 16531

Re: LIN decoding not reliable

Hi ge75el, I'm facing the same problem. Go into advanced settings and disable the Invert Packet Bits. This will cause to decode the data right. Unfortunatelly the GUI is somehow awkward and its hard to read the received bytes, because there are like: ABCDEFGH instead of AB CD EF GH. Vojtech PS: disa...
by Vojtech
Thu Oct 30, 2014 6:53 am
Forum: PicoScope 6 for Windows
Topic: 4227 - LIN Logic Analysis
Replies: 5
Views: 5604

4227 - LIN Logic Analysis

Hello guys, I'm using the 4227 PicoScope with SW version 6.9.18.1. I'm measuring data over LIN bus and I wanted to use the logical analyzer, so I turned it on but I was surprised about the result. The scope was not able to decode the data or better to say it decodes it wrong. I was investigating it,...