Search found 3 matches

by talktronics
Tue Aug 01, 2017 3:52 pm
Forum: PicoScope 6 for Windows
Topic: How to control vertical range of Spectral Mode?
Replies: 5
Views: 6100

Re: How to control vertical range of Spectral Mode?

As Michael pointed out, scaling, etc. does not change the situation.
by talktronics
Thu May 14, 2015 3:47 pm
Forum: Getting Started
Topic: Crosstalk on 5224B
Replies: 1
Views: 3192

Crosstalk on 5224B

I am using both channels to look at digital signals in 1MHz to 50MHz range. I see at least 20% crosstalk of one channel superimposed on the other channel. Both channels using provided scope probes, grounded at the board or not I see same thing. Is there a common-ground problem? I ask because I can l...
by talktronics
Sat Jun 28, 2014 3:14 am
Forum: PicoScope 6 for Windows
Topic: How to control vertical range of Spectral Mode?
Replies: 5
Views: 6100

How to control vertical range of Spectral Mode?

I've been using 5244B for performance measurements of an amplifier used for position controller. Looking at the noise levels, in Spectral Mode, there are situations where the baseline of the spectral plot (x-axis) is chopped off. There does not seem to be a way to set the vertical axis range from mi...