Search found 19 matches

by want2know
Fri Sep 13, 2013 9:28 am
Forum: USB PC Data Loggers
Topic: Omit data and display graph real time
Replies: 2
Views: 4853

Omit data and display graph real time

Dear Sir, As data logging is going on, the graph is displayed real time and it works perfectly. There is incident where I would like to omit two measurement points which are out of range due to loose connection etc, is there any way I can just omit the two datas so that Picolog still displays the co...
by want2know
Wed Sep 11, 2013 8:11 am
Forum: USB PC Data Loggers
Topic: Connection between ADC-20 and Electronic Load
Replies: 6
Views: 7580

Re: Connection between ADC-20 and Electronic Load

Dear Sir, I would like to check with you if ADC-20 and terminal boards can be used along with any programmable electronic load? If yes, what are the? What I can see is from the device (please see attached file), there are only two terminals where I can connect to a DC source (in this case a battery)...
by want2know
Wed Sep 11, 2013 8:07 am
Forum: USB PC Data Loggers
Topic: single-ended vs differential input in ADC-20 & terminal boar
Replies: 6
Views: 9531

Re: single-ended vs differential input in ADC-20 & terminal

Dear Sir, Ok, just want to be sure, I refer to the Picolog Data Logger Software manual page 58, Differential input If you wish to measure the voltage difference between adjacent channels, check this box. This mode applies to channels 1, 3, 5, and 7. For example, if differential input is enabled for ...
by want2know
Tue Sep 10, 2013 2:51 pm
Forum: USB PC Data Loggers
Topic: single-ended vs differential input in ADC-20 & terminal boar
Replies: 6
Views: 9531

Re: single-ended vs differential input in ADC-20 & terminal

1. Previously I was measuring temperature, voltage and current using single-ended configurations. Now I want to use differential configuration for only the current measurement, the temperature and voltage remains in single-ended configurations. Is it possible to use the combination of single-ended a...
by want2know
Tue Sep 10, 2013 2:23 pm
Forum: USB PC Data Loggers
Topic: Connection between ADC-20 and Electronic Load
Replies: 6
Views: 7580

Re: Connection between ADC-20 and Electronic Load

Dear Sir, This is a different question than the other thread but I got the same reply from you. Dear Sir/Madam, I am doing Lithium ion cell discharge test, I want to use ADC 20 as well as terminal board for voltage, current and temperature measurement. The battery is going to discharge through micro...
by want2know
Tue Sep 10, 2013 7:52 am
Forum: USB PC Data Loggers
Topic: Connection between ADC-20 and Electronic Load
Replies: 6
Views: 7580

Re: Connection between ADC-20 and Electronic Load

Could someone please have a look?
by want2know
Mon Sep 09, 2013 2:49 pm
Forum: USB PC Data Loggers
Topic: single-ended vs differential input in ADC-20 & terminal boar
Replies: 6
Views: 9531

single-ended vs differential input in ADC-20 & terminal boar

Dear Sir/Madam, Previously I was using ADC 20 as well as terminal board successfully for single-ended voltage measurement cause all inputs share the same ground point. What I wanted to do now is differential input, I could not find the details in the manual on how to do it, what are the adjustments ...
by want2know
Fri Sep 06, 2013 2:14 pm
Forum: USB PC Data Loggers
Topic: Connection between ADC-20 and Electronic Load
Replies: 6
Views: 7580

Connection between ADC-20 and Electronic Load

Dear Sir/Madam, I am doing Lithium ion cell discharge test, I want to use ADC 20 as well as terminal board for voltage, current and temperature measurement. The battery is going to discharge through microprocessor controlled loads or programmable DC Electronic Load instead of using resistor. (I use ...
by want2know
Fri Aug 16, 2013 2:18 pm
Forum: USB PC Data Loggers
Topic: Cell Charging and Discharging Monitoring using ADC-20
Replies: 12
Views: 22481

Re: Cell Charging and Discharging Monitoring using ADC-20

Dear Sir, Can I use the Terminal Board for Charging and Discharging at the SAME time? For example, Channel 1: voltage measurement for charging using Battery A Channel 2: voltage measurement for discharging using Battery B The terminal negative for BOTH Battery A and Battery B are connected to the SM...
by want2know
Fri Aug 16, 2013 8:13 am
Forum: USB PC Data Loggers
Topic: plw32.exe has stopped working, maximum calculated parameter?
Replies: 1
Views: 3289

plw32.exe has stopped working, maximum calculated parameter?

Dear Sir/Madam, I am using Picolog data logging for ADC-20 and terminal board. While setting up the new data logging, I am using three channels with 5 calculated parameters, whenever I input for "Calculated parameter" for the fourth parameter, I will get this error dialog box "plw32.exe has stopped ...
by want2know
Tue Aug 13, 2013 8:25 am
Forum: USB PC Data Loggers
Topic: plw32.exe has stopped working
Replies: 1
Views: 3620

plw32.exe has stopped working

Dear Sir/Madam, I am using Picolog data logging for ADC-20 and terminal board. During the data logging, at "Spreadsheet", whenever I click "Write to disk", I will get this error "plw32.exe has stopped working"and the program would have to be terminated. If I didnt click that button,it is working per...
by want2know
Fri Aug 09, 2013 3:01 pm
Forum: USB PC Data Loggers
Topic: Cell Charging and Discharging Monitoring using ADC-20
Replies: 12
Views: 22481

Re: Cell Charging and Discharging Monitoring using ADC-20

Could someone please have a look?
by want2know
Thu Aug 08, 2013 12:30 pm
Forum: USB PC Data Loggers
Topic: Cell Charging and Discharging Monitoring using ADC-20
Replies: 12
Views: 22481

Re: Cell Charging and Discharging Monitoring using ADC-20

Dear Sir, I am going to measure THREE parameters at the SAME time: voltage, current and temperature (using LM35DZ IC). In the Terminal Board, there are 16 channels totally (from Channel 1 to Channel 16), I have no problem with this since I only need three and there are 16 available. My question is, ...
by want2know
Wed Aug 07, 2013 7:01 pm
Forum: USB PC Data Loggers
Topic: Cell Charging and Discharging Monitoring using ADC-20
Replies: 12
Views: 22481

Re: Cell Charging and Discharging Monitoring using ADC-20

Thank you very much for the detailed explanation, Sir. 1. I now understand the reason behind this. If I understand correctly, this can only be applied for discharging. For voltage and current measurement during Charging purpose, I don't connect to load, but to power supply instead, so how should I d...