Search found 12 matches

by TimB
Mon Jun 04, 2018 9:00 am
Forum: PicoScope 6 for Windows
Topic: PicoScope 9000 database file save
Replies: 8
Views: 6582

Re: PicoScope 9000 database file save

Thanks for the update.
I will make our 9000 Series Product Manager aware of your comments and if we have any changes to the software will post an update for you.
by TimB
Wed May 30, 2018 1:01 pm
Forum: PicoScope 6 for Windows
Topic: PicoScope 9000 database file save
Replies: 8
Views: 6582

Re: PicoScope 9000 database file save

]Please see screenshot. I have the Display Menu on the right and have selected Infin Persistence On the left I have the Save / Recall and have selected Ch1 as Source and then clicked on Save which has brought up the Save Waveform As box where you can save in the displayed formats as shown. [attachme...
by TimB
Wed May 23, 2018 8:22 am
Forum: PicoScope 6 for Windows
Topic: PicoScope 9000 database file save
Replies: 8
Views: 6582

Re: PicoScope 9000 database file save

I am running Win10 with latest updates and the current software release for the 9200 (2.6.0) which you can obtain from our downloads page on this website. You will find the download under the discontinued products tab. All seems to be working well with a selection of File Types available in the drop...
by TimB
Mon May 21, 2018 2:49 pm
Forum: PicoScope 6 for Windows
Topic: PicoScope 9000 database file save
Replies: 8
Views: 6582

Re: PicoScope 9000 database file save

Can you please advise which model of PicoScope you are using and also the software version running please?
by TimB
Wed Dec 06, 2017 9:22 am
Forum: Pre-Sales Advice
Topic: PicoSample 3 software in demo mode
Replies: 2
Views: 4258

Re: PicoSample 3 software in demo mode

Yes...
If you go to the downloads page on the website and download PS3 then you can open in Demo Mode.
You can also change the instrument by going to Help - About - Instrument Info
by TimB
Thu Jul 14, 2016 2:07 pm
Forum: Introductions
Topic: Introduction and software for taking measurements
Replies: 5
Views: 7045

Re: Introduction and software for taking measurements

Having a problem running the application and when starting capture receive an Unhandled Exception message hopefully you can assist with. Please see below: See the end of this message for details on invoking just-in-time (JIT) debugging instead of this dialog box. ************** Exception Text ******...
by TimB
Wed Nov 27, 2013 8:42 am
Forum: USB PC Oscilloscopes
Topic: Signal Generator not working for low frequencies
Replies: 2
Views: 3579

Re: Signal Generator not working for low frequencies

Hi

Could you save your settings in PicoScope6 and then email the ps data file to support@picotech.com and we can investigate further for you.
by TimB
Wed Aug 14, 2013 12:02 pm
Forum: PicoLog
Topic: Logging from 3 TC08 USB units
Replies: 1
Views: 3524

Re: Logging from 3 TC08 USB units

I have connected 3 TC-08's together in our Lab and have activated 24 Channels. It is correct that in the PLW Spreadsheet view there are 15 Channels visible which is a viewing limitation, when the Spreadsheet is saved all 24 Channels are saved and can be viewed on the spreadsheet. For viewing as the ...
by TimB
Mon Aug 12, 2013 10:20 am
Forum: Pre-Sales Advice
Topic: Oscilloscope for I2C and FlexRay
Replies: 1
Views: 4277

Re: Oscilloscope for I2C and FlexRay

The 2205 MSO has Two Input Channels that can be used for Serial Bus Decoding and in addition 16 Digital Channels that provide Logic Analyser functionality. You can download PicoScope6 software from the website and select demo mode to get a feel for the software. We also have instructional video's in...
by TimB
Mon Aug 12, 2013 10:08 am
Forum: PicoScope 6 for Windows
Topic: HELP! adjusting x axils of spectrum view
Replies: 1
Views: 2666

Re: HELP! adjusting x axils of spectrum view

I have just tested using this Set Up and all seems to work well. When you adjust the "Collection Time" setting this changes the X Axis settings in both Scope and Spectrum Views. Try using the Auto Setup initially and then adjust settings from there. May also be worth checking that you are using the ...
by TimB
Fri Aug 02, 2013 1:50 pm
Forum: PicoLog
Topic: PLW Recorder alarm LED resize
Replies: 1
Views: 3672

Re: PLW Recorder alarm LED resize

It is not possible to resize the Alarm LED in PicoLog.
You can also assign an audible alarm if that would assist you.
by TimB
Fri Aug 02, 2013 1:21 pm
Forum: USB PC Data Loggers
Topic: Cell Charging and Discharging Monitoring using ADC-20
Replies: 12
Views: 22481

Re: Cell Charging and Discharging Monitoring using ADC-20

The ADC-20 Terminal Board is different to the ADC-16.
Could you please contact: support@picotech.com and we will be able to forward more information for this application.