Search found 3 matches

by Sinbad22
Fri Mar 30, 2012 11:03 am
Forum: Pre-Sales Advice
Topic: Choosing the right equipment
Replies: 5
Views: 7814

Re: Choosing the right equipment

The 2204 has an 8000 sample memory. What time base do I need to get accuracy to equal or be a bit better than 1us? I looked at the PicoScope6 software and I saw that you can save 10000 buffers. Why does the time start at zero for each buffer instead of increasing? Why are the buffers all stored in s...
by Sinbad22
Fri Mar 30, 2012 1:01 am
Forum: Pre-Sales Advice
Topic: Choosing the right equipment
Replies: 5
Views: 7814

Re: Choosing the right equipment

The frequency of the signal is 50hz. The max amplitude of the signal is 5 volts and 8bit resolution is required.
What is the cheapest oscilloscope that will do this?
by Sinbad22
Sun Mar 25, 2012 4:26 am
Forum: Pre-Sales Advice
Topic: Choosing the right equipment
Replies: 5
Views: 7814

Choosing the right equipment

Hi, Please ignore my last post. I want to record a signal that will be sent to a servo. This means that I only need to use one channel. I want a sample rate of at least 1MS/sec to give accuracy of at least 1 microsecond. I want to record this data because I am interested in working out the high puls...