Search found 4482 matches

by Martyn
Mon Apr 15, 2024 3:25 pm
Forum: PicoScope 7 for Windows, Linux and Mac
Topic: PICOSCOPE 2204A NOT SUPPORTED with PICOSCOPE 7
Replies: 1
Views: 37

Re: PICOSCOPE 2204A NOT SUPPORTED with PICOSCOPE 7

The PicoScope 2204a is not supported in the Automotive Software, you need to download the T&M version of PicoScope from the download page linked at the top of this page.
by Martyn
Mon Apr 15, 2024 7:00 am
Forum: PicoScope 7 for Windows, Linux and Mac
Topic: PicoSoft 7 manual
Replies: 13
Views: 7868

Re: PicoSoft 7 manual

There will be gaps in data collection between the 40 waveforms so it would not make sense to stitch them together.
by Martyn
Wed Apr 10, 2024 10:40 am
Forum: USB PC Oscilloscopes
Topic: PicoLog Setup
Replies: 1
Views: 53

Re: PicoLog Setup

Which device do you have?
Can you post screen shots showing this effect, and possible a psdata file and a picolog file so we can see the setup of the software.

I expect that the issue will be the much slower sampling speed of PicoLog compared with PicoScope.
by Martyn
Fri Apr 05, 2024 11:52 am
Forum: PicoScope 7 for Windows, Linux and Mac
Topic: Show channel voltages at specific time
Replies: 4
Views: 170

Re: Show channel voltages at specific time

We have a feature request in for this to be added. In the meantime there is a workaround that can give this value using measurements. If you add a measurement for "Maximum" select "Between rulers", then place the time rulers close to each other and lock them you will get the value at the rulers. Now...
by Martyn
Thu Apr 04, 2024 11:18 am
Forum: PicoScope 7 for Windows, Linux and Mac
Topic: Notes Field in Save Dialog
Replies: 2
Views: 131

Re: Notes Field in Save Dialog

Can you confirm the version of the software you are using, and which Operating System you have.
by Martyn
Tue Apr 02, 2024 1:58 pm
Forum: PicoScope 7 for Windows, Linux and Mac
Topic: Waveform setup when switching to persistence modes
Replies: 1
Views: 272

Re: Waveform setup when switching to persistence modes

Which version of the software are you using?

When I switch from Scope to Peristence and back again in the Instruments panel the settings persist.
by Martyn
Tue Apr 02, 2024 1:53 pm
Forum: .Net Languages (C#, VB.Net, .)
Topic: WFP's UI cant not using the driver of ps4000s device.
Replies: 1
Views: 256

Re: WFP's UI cant not using the driver of ps4000s device.

Can you provide some example code that shows this issue?

You can either post it here or send it directly to the team support@picotech.com
by Martyn
Tue Apr 02, 2024 5:11 am
Forum: Python
Topic: PICO_NOT_FOUND
Replies: 1
Views: 168

Re: PICO_NOT_FOUND

Customer reported under a different forum topic that they were using ps5000 and not ps5000a code.
by Martyn
Tue Mar 26, 2024 12:41 pm
Forum: PicoScope 7 for Windows, Linux and Mac
Topic: ETS Trigger Option not showing
Replies: 4
Views: 228

Re: ETS Trigger Option not showing

I would expect the reason you are not seeing ETS is that you have the hardware resolution set to 12 bit or higher. ETS is only available in 8 bit mode.
by Martyn
Tue Mar 26, 2024 9:07 am
Forum: PicoLog
Topic: Picolog 6 has it changed with recent updates
Replies: 1
Views: 506

Re: Picolog 6 has it changed with recent updates

Graphing all channels would have been the default setup, although you can split channels across four different axes, so that may be where you recollection of four came from. I will feed back your comments about a bar graph display, sounds an interesting idea, but I can't guarantee if or when it woul...
by Martyn
Tue Mar 26, 2024 8:55 am
Forum: USB PC Oscilloscopes
Topic: Picoscope 4262 ADC values
Replies: 1
Views: 278

Re: Picoscope 4262 ADC values

This will be due to the digital scaling applied to all the values returned from the scope. This digital scaling is necessary to ensure that when a fixed value of say 1V is present at the input of the scope that the software will report this as 1V. The values used for digital scaling are calculated d...
by Martyn
Fri Mar 22, 2024 2:43 pm
Forum: USB PC Oscilloscopes
Topic: Resolution enhancement and trigger threshold
Replies: 5
Views: 268

Re: Resolution enhancement and trigger threshold

If you remove the resolution enhancement so that you are seeing raw values, you will see that every trigger is actually at the same value of 471.2mV as shown by the masurement I have added which is maximum between rulers. TriggerPoint.png this applies to the buffers you mentioned but also ones which...
by Martyn
Fri Mar 22, 2024 7:11 am
Forum: USB PC Oscilloscopes
Topic: Picoscope Firmware Version
Replies: 4
Views: 204

Re: Picoscope Firmware Version

The scope only contains software to manage the loading of the actual running image, it does not retain this after it is powered down. This image file is contained in the dll and loaded into the scope when you issue the Open command in your own application, or when you start the PicoScope application...
by Martyn
Fri Mar 22, 2024 7:03 am
Forum: USB PC Oscilloscopes
Topic: Resolution enhancement and trigger threshold
Replies: 5
Views: 268

Re: Resolution enhancement and trigger threshold

Can you post psdata files showing what you mean, then we can see the actual data and the setup of the scope and software.