Search found 7 matches

by makila
Fri Jan 18, 2008 12:18 am
Forum: PicoScope 5
Topic: Pico Scope locks up
Replies: 8
Views: 10495

Tom Roberts of Autonerdz figured out the problem.

RFI was interfering with the usb converter. A grounded tinfoil shield cleared up the signal and stopped the crashing...

Image


Loren
by makila
Wed Jan 16, 2008 10:13 pm
Forum: PicoScope 5
Topic: Pico Scope locks up
Replies: 8
Views: 10495

I got the new usb converter and PicoScope is no longer locking up and crashing. However, when looking at ignition primary volts & amps the data displayed is scrambled and does not reflect reality. I set the ADC 212/3 to view primary V & A on a vehicle, set up PicoScope 5 to save on trigger, and got ...
by makila
Tue Jan 15, 2008 5:32 pm
Forum: PicoScope 5
Topic: Pico Scope locks up
Replies: 8
Views: 10495

I don't think that high voltage is making it out of the ADC 212/3, I think that the parallel to usb doesn't understand the voltage out of range signal that is being sent to it encoded as parallel data. If I understand correctly how it works (and I probably don't :shock: ), the ADC 212/3 is sampling ...
by makila
Tue Jan 15, 2008 3:36 pm
Forum: PicoScope 5
Topic: Pico Scope locks up
Replies: 8
Views: 10495

Ok... I've been looking into this further and have come up with some further information. I was able to set the PicoScope back up on an older PC that has both usb and parallel ports. I also noticed that there seemed to be a pattern as to when the PicoScope software would lock up --> it would very co...
by makila
Mon Jan 14, 2008 6:51 pm
Forum: PicoScope 5
Topic: Pico Scope locks up
Replies: 8
Views: 10495

Hello Tom -

Yep... that would be me. I'll give you a call. Thanks!

Loren
by makila
Mon Jan 14, 2008 5:21 pm
Forum: PicoScope 5
Topic: Pico Scope locks up
Replies: 8
Views: 10495

Just to add a little more to my post above...

The exact same problem occurs when using PicoScope R6.0.12.2

Loren
by makila
Thu May 19, 2005 2:06 pm
Forum:
Topic: adc 212/100 update shot on long timebase
Replies: 23
Views: 29245

I'm not sure if I'm reading this right but... Guset wrote: so i put the -50 into block mode with 25000 samples [my default] and ran it at 1 sec per div. the screen updates 1 time every 14 seconds???? tell me thats not wacked! 1 sec/div = 10 seconds of total data It took 14 seconds (i.e. less than 20...