ps3000_close_unit ... open-> hang

Post general discussions on using our drivers to write your own software here
Post Reply
Guest

ps3000_close_unit ... open-> hang

Post by Guest »

Hi,

it seems like the PicoScope Driver hangs from time to time when I use ps3000_close_unit imediately after other calls.
This happens some times in some runs with doozends opens and closings of the device with some measurements between.
Allways waiting 1 second before closing the device in the loop seems to solve the problem.
The hang without appears on the next ps3000_open...

Device is 3204 system XP

markB
Site Admin
Site Admin
Posts: 83
Joined: Tue Mar 27, 2007 9:43 am
Location: Cambridgeshire,UK

Post by markB »

Which calls do you make before closing the unit? Is it any particular calls that cause the dll to hang?

Mark

Post Reply