PS4000A_ID_Block_Example.m
Code: Select all
set(triggerGroupObj, 'autoTriggerMs', 0);
set(triggerGroupObj, 'delay', 0);
% Channel : 0 (ps4000aEnuminfo.enPS4000AChannel.PS4000A_CHANNEL_A)
% Threshold : 1700 (mV)
% Direction : 2 (ps4000aEnuminfo.enPS4000AThresholdDirection.PS4000A_RISING)
[status.setSimpleTrigger] = invoke(triggerGroupObj, 'setSimpleTrigger', 0, 1700, 2);
Code: Select all
Copyright (C) Pico Technology Ltd. 2014 - 2015
PicoScope 4000 Series (A API) MATLAB Instrument Driver
Number of units found: 1
Serial number(s): CS570/011
Opening PicoScope 4000 Series device...
Instrument Device Object Using Driver : picotech_ps4000a_generic.mdd
Instrument Information
Type: Oscilloscope
Manufacturer: Pico Technology Ltd.
Model: PicoScope 4000 Series (A API)
Driver Information
DriverType: MATLAB generic
DriverName: picotech_ps4000a_generic.mdd
DriverVersion: 1.1.26
Communication State
Status: open
Setting Device Parameters...
Default Channel Setup:-
-----------------------
Channel A:-
Enabled: True
Coupling: DC
Range: 5V
Analogue Offset: 0.0V
Channel B:-
Enabled: True
Coupling: DC
Range: 5V
Analogue Offset: 0.0V
Turning off trigger...
Default Block mode parameters:-
Timebase index : 79
Time Interval: 1540.0 ns
Number of pre-trigger samples: 0
Number of post-trigger samples: 1000000
Total number of samples: 1000000
Default Streaming mode parameters:-
Streaming interval: 1.00e-06 s
Streaming auto stop: 1
Initialisation complete.
Connected to PicoScope 4000 Series device:-
Instrument Model: 4225
Batch/Serial Number: CS570/0119
Analogue Channels: 2
Bandwidth: 20 MHz
Buffer memory: 250 MS
Maximum sampling rate: 400 MS/s
Signal Generator Type: None
runBlock:- Collecting block of data:
Timebase: 79
Pre-trigger samples: 0
Post-trigger samples: 1000000
runBlock: Waiting for device to become ready...
runBlock: Device ready.
getBlockData: Setting up data buffers...
getBlockData: Retrieving data...
getBlockData: Assigning data to array and converting to millivolts.
getBlockData: Data succesfully retrieved.
Connection to PicoScope 4225 with serial number CS570/0119 closed successfully.
Libraries unloaded successfully.
I would check the code to see if you are actually setting a triggerMoJou wrote:Code: Select all
Turning off trigger...
Code: Select all
connect(ps4000aDeviceObj);
Code: Select all
Default Channel Setup:-
-----------------------
(...)
Turning off trigger...
Code: Select all
triggerGroupObj = get(ps4000aDeviceObj, 'Trigger');
triggerGroupObj = triggerGroupObj(1);
set(triggerGroupObj, 'autoTriggerMs', 0);
[status.setSimpleTrigger] = invoke(triggerGroupObj, 'setSimpleTrigger', 0, thresholdvalue, 2);
Code: Select all
%% PicoScope 4000 Series (A API) Instrument Driver Oscilloscope Block Data Capture Example
% This is an example of an instrument control session using a device
% object. The instrument control session comprises all the steps you
% are likely to take when communicating with your instrument.
%
% These steps are:
%
% # Create a device object
% # Connect to the instrument
% # Configure properties
% # Invoke functions
% # Disconnect from the instrument
%
% To run the instrument control session, type the name of the file,
% PS4000A_ID_Block_Example, at the MATLAB command prompt.
%
% The file, PS4000A_ID_BLOCK_EXAMPLE.M must be on your MATLAB PATH. For
% additional information on setting your MATLAB PATH, type 'help addpath'
% at the MATLAB command prompt.
%
% *Example:*
% PS4000A_ID_Block_Example;
%
% *Description:*
% Demonstrates how to call functions in order to capture a block of
% data from a PicoScope 4000 Series Oscilloscope using the underlying
% 'A' API.
%
% *See also:* |
%
% *Copyright:* (C) Pico Technology Limited 2014 - 2015. All rights reserved.
%% Suggested Input Test Signal
% This example was published using the following test signal:
%
% * Channel A: 4Vpp, 5Hz sine wave
%% Clear Command Window
clc;
%% Load Configuration Information
PS4000aConfig;
%% Device Connection
% Create a device object.
% The serial number can be specified as a second input parameter.
ps4000aDeviceObj = icdevice('picotech_ps4000a_generic.mdd', '');
% Connect device object to hardware.
connect(ps4000aDeviceObj);
%% Set Channels
% Default driver settings applied to channels are listed below -
% use ps4000aSetChannel to turn channels on or off and set voltage ranges,
% coupling, as well as analogue offset.
% In this example, data is only collected on Channel A so default settings
% are used and channels B to H are switched off.
% Channels : 1 - 7 (ps4000aEnuminfo.enPS4000AChannel.PS4000A_CHANNEL_B - PS4000A_CHANNEL_H)
% Enabled : 0
% Type : 1 (ps4000aEnuminfo.enPS4000ACoupling.PS4000A_DC)
% Range : 8 (ps4000aEnuminfo.enPS4000ARange.PS4000A_5V)
% Analogue Offset: 0.0
% Execute device object function(s).
[status.setChB] = invoke(ps4000aDeviceObj, 'ps4000aSetChannel', 1, 0, 0, 4, 0.0);
if(ps4000aDeviceObj.channelCount == PicoConstants.QUAD_SCOPE || ps4000aDeviceObj.channelCount == PicoConstants.OCTO_SCOPE)
[status.setChC] = invoke(ps4000aDeviceObj, 'ps4000aSetChannel', 2, 0, 1, 8, 0.0);
[status.setChD] = invoke(ps4000aDeviceObj, 'ps4000aSetChannel', 3, 0, 1, 8, 0.0);
end
if(ps4000aDeviceObj.channelCount == PicoConstants.OCTO_SCOPE)
[status.setChE] = invoke(ps4000aDeviceObj, 'ps4000aSetChannel', 4, 0, 1, 8, 0.0);
[status.setChF] = invoke(ps4000aDeviceObj, 'ps4000aSetChannel', 5, 0, 1, 8, 0.0);
[status.setChG] = invoke(ps4000aDeviceObj, 'ps4000aSetChannel', 6, 0, 1, 8, 0.0);
[status.setChH] = invoke(ps4000aDeviceObj, 'ps4000aSetChannel', 7, 0, 1, 8, 0.0);
end
%% Verify Timebase Index and Maximum Number of Samples
% Driver default timebase index used - use ps4000aGetTimebase2 to query the
% driver as to suitability of using a particular timebase index and the
% maximum number of samples available in the segment selected (the buffer
% memory has not been segmented in this example) then set the 'timebase'
% property if required.
%
% To use the fastest sampling interval possible, set one analogue channel
% and turn off all other channels.
%
% Use a while loop to query the function until the status indicates that a
% valid timebase index has been selected. In this example, the timebase
% index of 79 is valid.
% Initial call to ps4000aGetTimebase2 with parameters:
% timebase : 79
% segment index : 0
status.getTimebase2 = PicoStatus.PICO_INVALID_TIMEBASE;
timebaseIndex = get(ps4000aDeviceObj, 'timebase');
while(status.getTimebase2 == PicoStatus.PICO_INVALID_TIMEBASE)
[status.getTimebase2, timeIntervalNanoSeconds, maxSamples] = invoke(ps4000aDeviceObj, 'ps4000aGetTimebase2', timebaseIndex, 0);
if(status.getTimebase2 == PicoStatus.PICO_OK)
break;
else
timebaseIndex = timebaseIndex + 1;
end
end
set(ps4000aDeviceObj, 'timebase', timebaseIndex);
%% Set Simple Trigger
% Set a trigger on Channel A, with an auto timeout - the default value for
% delay is used.
% Trigger properties and functions are located in the Instrument
% Driver's Trigger group.
triggerGroupObj = get(ps4000aDeviceObj, 'Trigger');
triggerGroupObj = triggerGroupObj(1);
% Set the autoTriggerMs property in order to automatically trigger the
% oscilloscope after 1 second if a trigger event has not occurred. Set to 0
% to wait indefinitely for a trigger event.
set(triggerGroupObj, 'autoTriggerMs', 0);
set(triggerGroupObj, 'delay', 0);
% Channel : 0 (ps4000aEnuminfo.enPS4000AChannel.PS4000A_CHANNEL_A)
% Threshold : 500 (mV)
% Direction : 2 (ps4000aEnuminfo.enPS4000AThresholdDirection.PS4000A_RISING)
[status.setSimpleTrigger] = invoke(triggerGroupObj, 'setSimpleTrigger', 0, 500, 2);
%% Set Block Parameters and Capture Data
% Capture a block of data and retrieve data values for Channel A.
% Block data acquisition properties and functions are located in the
% Instrument Driver's Block group.
blockGroupObj = get(ps4000aDeviceObj, 'Block');
blockGroupObj = blockGroupObj(1);
% Set pre-trigger and post-trigger samples as required
% The default of 0 pre-trigger and 1 million post-trigger samples is used
% in this example.
% set(ps4000aDeviceObj, 'numPreTriggerSamples', 0);
% set(ps4000aDeviceObj, 'numPostTriggerSamples', 2e6);
%%
% This example uses the _runBlock_ function in order to collect a block of
% data - if other code needs to be executed while waiting for the device to
% indicate that it is ready, use the _ps4000aRunBlock_ function and poll
% the _ps4000aIsReady_ function.
% Capture a block of data:
%
% segment index: 0 (The buffer memory is not segmented in this example)
[status.runBlock] = invoke(blockGroupObj, 'runBlock', 0);
% Retrieve data values:
%
% start index : 0
% segment index : 0
% downsampling ratio: 1
% downsampling mode : 0 (ps4000aEnuminfo.enPS4000ARatioMode.PS4000A_RATIO_MODE_NONE)
% Provide additional output arguments for the remaining channels e.g. chB
% for Channel B
[numSamples, overflow, chA] = invoke(blockGroupObj, 'getBlockData', 0, 0, 1, 0);
% Stop the device
[status.stop] = invoke(ps4000aDeviceObj, 'ps4000aStop');
%% Process Data
% Plot data values returned from the device.
figure1 = figure('Name','PicoScope 4000 Series Example - Block Mode Capture', ...
'NumberTitle', 'off');
% Calculate sampling interval (nanoseconds) and convert to milliseconds
% Use the timeIntervalNanoSeconds output from the ps4000aGetTimebase2
% function or calculate it using the main Programmer's Guide.
timeNs = double(timeIntervalNanoSeconds) * double(0:numSamples - 1);
timeMs = timeNs / 1e6;
% Channel A
plot(timeMs, chA);
title('Block Data Acquisition');
xlabel('Time (ms)');
ylabel('Voltage (mV)');
grid on;
legend('Channel A');
%% Disconnect Device
% Disconnect device object from hardware.
disconnect(ps4000aDeviceObj);
delete(ps4000aDeviceObj);