ADC-216 accuracy specs

Post any questions about our serial port products
Post Reply
Jeffrey Young

ADC-216 accuracy specs

Post by Jeffrey Young »

What is the channel accuracy for a differential measurment? ie the accuracy of a measurment made from the difference of two measurments.

Jeff.

User avatar
matthew
Advanced User
Advanced User
Posts: 109
Joined: Wed Sep 25, 2002 9:35 am
Location: Cambridgeshire, UK

Post by matthew »

Hi Jeff,

I assume you meant the ADC-16 here, as the ADC-216 does not measure differential signals (it has two single ended, common ground channels).

In the ADC-16, the voltages are combined on the analogue side of the ADConverter, therefore the accuracy in differential mode is the same as the accuracy of the single-ended mode of operation - ie ±0.2%.

Best Regards,
Matt Everett

Pico Software Engineer

Post Reply