Monitoring Communications Bus

Which product is right for your exact requirements
Post Reply
CoreControls

Monitoring Communications Bus

Post by CoreControls »

I would like to monitor a communications bus set for 19.2 Kbps. I am interested in the ADC-40 or PicoScope 2202. Is one more suitable than the other with respect bandwidth or sampling rate, or will both work well?

Michael
Advanced User
Advanced User
Posts: 656
Joined: Thu Jul 07, 2005 12:41 pm
Location: St Neots, Cambridgeshire

Post by Michael »

Hello,

Thank you for your post.

The ADC40 has a maximum sampling rate of 20kS/sec, a bandwidth of 10KHz. The 2202 has a sampling rate of 20MS/sec, a bandwitdh of 2MHz.

The 2202 is far better as your bit rate is approaching your maximum sampling rate. You will get better, longer samples with the 2202 as the ADC40 has no memory or clock onboard.

Best regards,
Michael