Post by sarasgobba »

Hello, I've got picoscope 2205. Is it possible to connect it to Picolog software?
I need to make acoustic emission data logging for long time.
Many thanks in advance

Martyn
Site Admin
Site Admin
Posts: 4491
Joined: Fri Jun 10, 2011 8:15 am
Location: St. Neots

Re: Picoscope and Picolog

Post by Martyn »

The 2205 will work with both PicScope and PicLog software. You can download the latest versions from http://www.picotech.com/software.html
Martyn
Technical Support Manager

sarasgobba
Newbie
Posts: 0
Joined: Wed Apr 11, 2012 8:48 am

Re: Picoscope and Picolog

Post by sarasgobba »

With reference to my last info request, do you think picoscope 2205 could be suitable for long time recording (one month for example)?
Thank you for your support.

Martyn
Site Admin
Site Admin
Posts: 4491
Joined: Fri Jun 10, 2011 8:15 am
Location: St. Neots

Re: Picoscope and Picolog

Post by Martyn »

You will need a permanently powered PC, with hibernation/sleep disabled, and sufficient space to store the data you collect, but in principle yes.

What data are you collecting and at what sample interval ?
Martyn
Technical Support Manager

sarasgobba
Newbie
Posts: 0
Joined: Wed Apr 11, 2012 8:48 am

Re: Picoscope and Picolog

Post by sarasgobba »

I should make time monitoring of acoustic emission signals in concrete specimens subjected to restrained shrinkage. Thus, I want to use the acoustic emission activity for cracking detection, that could happen at a cracking age unknow. Therefore, it could be enough just to record the number of trigger theresold crossings! Do you think I can set-up this condition in picolog, in order to reduce the number of data recorded? The sample frequency shoul be about 2 MHz.
Thank you again,
Sara

Martyn
Site Admin
Site Admin
Posts: 4491
Joined: Fri Jun 10, 2011 8:15 am
Location: St. Neots

Re: Picoscope and Picolog

Post by Martyn »

Do you have any sample waveforms that show what you would be looking to log ? and how many triggers you would expect to get for the duration of the test ?
Martyn
Technical Support Manager

Post Reply