PicoScope 7 Software
Available on Windows, Mac and Linux
Code: Select all
TRIGGER_CONDITIONS conditions = {CONDITION_DONT_CARE ,
CONDITION_DONT_CARE,
CONDITION_DONT_CARE,
CONDITION_DONT_CARE,
CONDITION_TRUE,
CONDITION_DONT_CARE,
CONDITION_DONT_CARE };
stStatus = ps6000SetTriggerChannelConditions(handlePico,&conditions,1);
trigCha = RISING;
stStatus = ps6000SetTriggerChannelDirections(handlePico,NONE,NONE,NONE,trigCha,NONE,NONE);
ps6000SetTriggerChannelProperties(handle, &channelproperties,1,0,0);
where channelproperties = {1625/*threshold-high*/,
325/*hysteresis-high*/,
1625/*threshold-high*/,
325/*hysteresis-low*/,
PS5000_MAX_CHANNELS/*channel used*/,
LEVEL/*threshold mode*/
}
Code: Select all
TRIGGER_CONDITIONS conditions = {CONDITION_DONT_CARE ,
CONDITION_DONT_CARE,
CONDITION_DONT_CARE,
CONDITION_DONT_CARE,
CONDITION_DONT_CARE,
CONDITION_TRUE,
CONDITION_DONT_CARE };
Code: Select all
stStatus = ps6000SetTriggerChannelDirections(handlePico,NONE,NONE,NONE,NONE,NONE,trigCha);
Code: Select all
channelproperties = {1625 /*threshold-high*/,
325 /*hysteresis-high*/,
1625 /*threshold-high*/,
325 /*hysteresis-low*/,
PS6000_TRIGGER_AUX /*channel used*/,
PS6000_LEVEL /*threshold mode*/