Post by deymian »

Can I set an amplitude of an AWG between -250 mV +250 mV in a pico-scope 2203?

I probe that in PicoScope6 with a pico-scope 2203 I can't. Is this a software fail? Can I set the amplitude of an AWG lower than 250 mV using the API?

If i use an arbitrary AWG I can set amplitude near to 0, isn't it?

Thank's.

Martyn
Site Admin
Site Admin
Posts: 4491
Joined: Fri Jun 10, 2011 8:15 am
Location: St. Neots

Re: Pico-scope 2203 AWG Amplitude

Post by Martyn »

You can't set a value between -250mV and +250mV, this is a hardware limit and applies for Picoscope6 as well as software written to use the dll.