Reading Current using ADC 20 and 600A AC/DC Current Clamp

Post any questions you may have about our current range of USB data loggers
Post Reply
ADS

Reading Current using ADC 20 and 600A AC/DC Current Clamp

Post by ADS »

Hi All,

I have the (PP266) current clamp connected to the ADC 20. I have cut the plug off and connected the cable to channel 8 and AG.
However, i cannot get the clamp to measure any current.
Can anyone help?

Thanks

PeterF
Advanced User
Advanced User
Posts: 435
Joined: Thu Jun 07, 2007 10:53 am
Location: Cambridgeshire

Re: Reading Current using ADC 20 and 600A AC/DC Current Clamp

Post by PeterF »

Hi,
Are you trying to measure AC current? The ADC-20 is not fast enough to capture 50Hz. If you are measuring DC current then you should be getting 1mV read on the ADC-20 for each Amp through the clamp.
Regards,
PeterF.