Advanced Triggering does not work with my PicoScope

Forum for discussing PicoScope version 6 (non-automotive version)
Post Reply

Does Advanced Triggering work with your scope?

YES - PicoScope 2000 series
0
No votes
YES - PicoScope 3000/4000/9000 series
0
No votes
YES - ADC-XX series
0
No votes
YES - ADC-100/200 series
0
No votes
YES - Other
0
No votes
No - PicoScope 2000 series
2
67%
No - PicoScope 3000/4000/9000 series
1
33%
No - ADC-XX series
0
No votes
No - ADC-100/200 series
0
No votes
No - Other
0
No votes
 
Total votes: 3

Edwallace2
User
User
Posts: 4
Joined: Fri Apr 17, 2009 4:49 am

Advanced Triggering does not work with my PicoScope

Post by Edwallace2 »

I recently downloaded the latest version of the PicoScope software and tried out the new Advanced Triggering conditions using a demo scope.

But when I connect my PicoScope 2104 handheld scope to the software, the Advanced Triggering button (on the triggering toolbar) is disabled though the other features work properly.

Is this a hardware limitation, and is there a way to use advanced triggers with my scope? I would find the advanced options really useful in my work, which frequently involves tricky pulses and complex signals.

Thank you,
Edward.

-----------------------------------------------------------

PS: I've included a Poll so Pico Tech can gather statistics for debugging purposes.

ziko
Advanced User
Advanced User
Posts: 1705
Joined: Fri Dec 01, 2006 10:03 am
Location: St Neots

Post by ziko »

Hi well the poll is inaccurate as not all the 2000 series have advanced triggering, infact the 2205 is the only one that has advanced triggering, so its not a bug. The advanced triggering is a hardware feature within the FPGA. Just to be clear here are the devices that do have advanced triggering:

2205
3224,3424,3223,3423,3425
4224,4424, 4223,4423
5203,5204

Kind regards
Ziko

Technical Specialist

Edwallace2
User
User
Posts: 4
Joined: Fri Apr 17, 2009 4:49 am

ADC-212 support?

Post by Edwallace2 »

Hi ziko, and thank you very much for your prompt, informative and conclusive answer, though it is unfortunate that my device does not support advanced triggers.

I also have a Pico Tech ADC-212/50 somewhere, though I don't have access to it right now, would this support advanced triggers?

Thank you and best regards,
Edward.
Last edited by Edwallace2 on Fri Apr 17, 2009 3:41 pm, edited 1 time in total.

ziko
Advanced User
Advanced User
Posts: 1705
Joined: Fri Dec 01, 2006 10:03 am
Location: St Neots

Post by ziko »

Hi Edward,

Unfortunately none of our parallel ported oscilloscopes have got advanced triggers.

Kind regards
Ziko

Technical Specialist

Post Reply