Additonal function of dBr

Forum for discussing PicoScope version 6 (non-automotive version)
Post Reply
llshadow
User
User
Posts: 3
Joined: Fri Nov 21, 2008 8:44 am

Additonal function of dBr

Post by llshadow »

It is possible to add the dBr function in PicoScope (time & FFT)? E.g. dBm (600 ohm), dBV (re any voltage) refer to any input voltage value? It is very useful for audio & acoustic measurement applications.

ziko
Advanced User
Advanced User
Posts: 1705
Joined: Fri Dec 01, 2006 10:03 am
Location: St Neots

Post by ziko »

Hi llshadow,

This may or may not be useful but you can set to an arbitrary reference voltage. Are you looking to have a measured amplitude on once channel with reference to another channel?

Kind regards
Ziko

Technical Specialist

llshadow
User
User
Posts: 3
Joined: Fri Nov 21, 2008 8:44 am

Post by llshadow »

Hi ziko,

Thank you for your reply.

I've tried the "arbitrary reference voltage" settings and it works. Thank you.

But, it seems this function doesn't support in R5.20 with my old ADC-216.

There is a function in the Audio Precision (APWIN) to lock the input signal level to 0dBr by pressing "F4". - Just a little suggestion.

It is also a pity that, my new PicoScope 5203 (R6.1) cannot support log scale (x-frequency) in FFT analyzer.

ziko
Advanced User
Advanced User
Posts: 1705
Joined: Fri Dec 01, 2006 10:03 am
Location: St Neots

Post by ziko »

HI llshadow,

I have put your suggestion through to the relevant people.

Kind regards
Ziko

Technical Specialist