Test and Measurement Forum

PicoScope5000a multiple channel

Post your LabVIEW discussions here

PicoScope5000a multiple channel

Postby jw_666 » Wed Oct 04, 2017 8:25 pm

BLOCK DIAGRAM SCOPE VI.PNG

I have a PicoScope 5442B. I have been working to operate all the 4 channels in LabVIEW, but I could only operate
channel A and B; however channel C and D gave me straight line at "0" my block diagram is attached as png files.
jw_666
Newbie
 
Posts: 0
Joined: Thu Sep 28, 2017 3:08 pm

Re: PicoScope5000a multiple channel

Postby jw_666 » Thu Oct 05, 2017 12:15 pm

I forgot the probably more important image. Here it is.
Attachments
BLOCK DIAGRAM SCOPE VI.PNG
jw_666
Newbie
 
Posts: 0
Joined: Thu Sep 28, 2017 3:08 pm

Re: PicoScope5000a multiple channel

Postby jw_666 » Fri Oct 06, 2017 12:22 pm

Sorry I had the files labeled backwards. Also I realize this is not for steaming. Nonetheless I am unable to get channels C and D to display. Any suggestions after looking at the real block diagram?
Attachments
FRONT PANEL SCOPE VI.PNG
jw_666
Newbie
 
Posts: 0
Joined: Thu Sep 28, 2017 3:08 pm

Re: PicoScope5000a multiple channel

Postby jw_666 » Wed Oct 11, 2017 6:38 pm

I have not gotten any responses to my question. If requested I will post my question under a different topic.
I did manage to find a way to display all four channels.
I changed the “Number of channels” under “Device Info” in the “PicoScope5000aGetBlock.vi” to “4”

My nagging question is why isn’t or doesn’t the “Device Info” carry through from “PicoScope5000aOpen.vi” to “PicoScope5000aGetBlock.vi”?
I am posting my VI to help with any questions about my code.
Thanks in advance for any info you may be able to provide.
Attachments
PicoScope5000.zip
(23.05 KiB) Downloaded 10 times
jw_666
Newbie
 
Posts: 0
Joined: Thu Sep 28, 2017 3:08 pm

Re: PicoScope5000a multiple channel

Postby Hitesh » Thu Oct 12, 2017 8:12 am

Hi jw_666,

Apologies for a delay in someone getting a response back to you.

Please check the OpenUnit vi sub-vi in case there is an output which carries the device information as there were some changes made. You may need to link this to the settings sub-vi.

Please also ensure that you have the latest files from the GitHub repository.

Regards,
Hitesh

Technical Support Engineer
Hitesh
Site Admin
Site Admin
 
Posts: 2498
Joined: Tue May 31, 2011 3:43 pm
Location: St. Neots, Cambridgeshire