PicoScope for Straingauge sniffing :-P

Which product is right for your exact requirements
Post Reply
Meins321
User
User
Posts: 2
Joined: Mon Jul 17, 2017 7:35 am

PicoScope for Straingauge sniffing :-P

Post by Meins321 »

Dear PicoScope Users/Support,

does any one use a picoscope for strain gauge experimenting? The input voltage/sensitivity is usally very important..

i know i wont get 1uV measured but 1mv/div to 10mV/div should be possible even with a very slow rise time...which means i need lots of memmory?

Any advice would be nice!

Greetings Meins321

Gerry
PICO STAFF
PICO STAFF
Posts: 1145
Joined: Mon Aug 11, 2014 11:14 am

Re: PicoScope for Straingauge sniffing :-P

Post by Gerry »

Hi Meins321,

Have a look at the post here: post85231.html#p85231.

Regards,

Gerry
Gerry
Technical Specialist

Meins321
User
User
Posts: 2
Joined: Mon Jul 17, 2017 7:35 am

Re: PicoScope for Straingauge sniffing :-P

Post by Meins321 »

Thank you for your fast reply to my question!

I had a look at the PicoScope 4444, the specification says 12bit on the 10mV/div range.

As most industrial straingauges are 1mV/V, and 2,5V/5V/10V excitation as standard, i can get only 10mV as output voltage while applying maximum load.

Now if i put 1,12Kg on my 10Kg loadcell, the output signal should be 0,112V or 11,2mV.

Is it still possible to see fine details with an Picoscope 4444 in the micro volt range? To see what happens when i load the strain gauge only partially up.


I know there is noise, but just asking this as an experiment!

bennog
Advanced User
Advanced User
Posts: 206
Joined: Mon Nov 26, 2012 9:16 am
Location: Netherlands

Re: PicoScope for Straingauge sniffing :-P

Post by bennog »

I have tested this with my 4444 and a 10kg loadcell, and was able to see variations of a few grams.

Don't know the exact values anymore, later this year we are testing this with 4 positions in a very noisy machine.
The plan is to use 1 or 2kg cells because they are more sensitive. I am planning to do all filtering in software.
Stream data to my application at at least 100ks / sec or even 1ms / sec and then try to make sense of all the noise.

Benno