ADC-100 measures offset

Forum for discussing PicoScope (version 5)
Post Reply
Guest

ADC-100 measures offset

Post by Guest »

Hello I have just bought secondhand an ADC-100. The software works well however it sometimes jumps to a minimum voltage level offset when its operating. This is disconcerting and the only way to get to correct operation again is to close the software and restart. I have tried both versions for XP on your website and both do the same. Any ideas or a different (older) version would be helpful

ziko
Advanced User
Advanced User
Posts: 1705
Joined: Fri Dec 01, 2006 10:03 am
Location: St Neots

Post by ziko »

The ADC100 uses a parallel interface, due to the way the XP works it has problems with some PCs. The ADC100 was designed before in the days when DOS was used. The parallel port adapter may resolve your problem:

http://www.picotech.com/usb_parallel_port.html

This is designed to work on our products and only our products.

Kind regards
Ziko