Since 1991 we have been supplying the world with test and measurement equipment. At Pico we realize that your choice of test accessories can be almost as important as your choice of test equipment. Here you can purchase a variety of test and measurement accessories quickly and securely online.

PS016 12 V power adaptor with IEC leads

The PS016 is a replacement power supply for the PicoScope 6000E Series oscilloscopes. It is supplied in the PQ247 sales kit with the following IEC mains cables:

  • MI193 UK IEC lead, 1.8 m
  • MI194 EU IEC lead, 1.8 m
  • MI195 US IEC lead, 1.8 m
  • MI196 Australia/China IEC lead, 1.8 m
Image shows the black mains adaptor, with it's 4 separate IEC mains leads for UK, Euro, USA, China/Aus
In stock. Available for despatch.
£65
PS016 input electrical specifications
Input voltage Maximum voltage: 264 V AC
Normal voltage: 100~240 V AC
Minimum voltage: 90 V AC
Input frequency Maximum frequency: 63 Hz
Normal frequency: 50 to 60 Hz
Minimum frequency: 47 Hz
Input current 1.5 A max. at 115 V AC input with full load
0.75 A max. at 230 V AC input with full load
Energy-saving standard Average efficiency ≥ 89% under normal line input
No-load power consumption: ≤ 0.15 W at normal line input
10% load efficiency ≥ 79% under normal line input
Configuration 3-wire AC input (line, neutral, FG)
Line regulation Less than ± 1%, of rated output voltage at full load
Harmonic standard and power factor Complies with IEC 61000-3-2 Class D harmonic standard with input power over 75 W. Power factor > 0.95 at 100 V AC input and >0.9 at 240 V AC input at full load
PS016 output electrical specification
Output voltage and current Output voltage: 12 V
Current min: 0 A
Current max: 7 A
Load regulation at 12 V Output voltage range: 11.4 V to 12.6 V
Ripple and noise For 12 V output, ripple and noise will not exceed 240 mV (pk-pk)
Overvoltage protection 150% of the rated output voltage
Stability 2% maximum at constant load with constant input (after 30 minutes of operation)
PS016 general specification
Temperature Operating : 0 °C to 40 °C
Storage : –20 °C to 85 °C
Humidity Operating : 10 to 90 %
Storage: 5 to 90 %
Max. altitude 2000 m
Leakage current 250 µA, at 240 V AC (50 Hz)
Safety UL/CUL, TUV, CB, CE, FCC, EK, PSE, RCM, CU, BSMI, CCC
EMI CISPR 32, EN 55032 Class B
FCC PART 15 Class B
Physical size 137 mm x 59 mm x 34 mm
Net weight 450 g