Sample size with ADC-212/3

 
Post new topic   Reply to topic    Pico Technology Forum Index -> Pre-Sales Advice
Author Message
Guest






PostPosted: Fri Jan 25, 2008 1:16 am    Post subject: Sample size with ADC-212/3 Reply with quote

I would like to collect 150,000 sample length records sampled at 2 milliseconds per sample. Can I do this?

The Datalogger software web page states "When used with the ADC-212/3 up to 32 thousand samples per channel can be collected at full speed. At lower speeds up to a million readings can be collected." Is 2 milliseconds low enough to collect the 150,000 samples?

Is there a way to calculate the maximun number of sambles for various speeds?

Thanks
Back to top
gruntman
Guru
Guru


Joined: 28 Sep 2006
Posts: 88
Location: Garden City, KS USA

PostPosted: Fri Jan 25, 2008 10:38 pm    Post subject: Reply with quote

Hello,

With the ADC-212/3 you may use the PicoLog software to achieve what you are wanting to do. You may select a sampling rate up to 1 ms sampling rate and log at this speed for up to 1 million samples.

Regards,

Richard Boyd
Technical Specialist
http://www.pc-oscilloscopes.com
Back to top