PC3424 input isolation / use with ADF25A

 
Post new topic   Reply to topic    Pico Technology Forum Index -> Pre-Sales Advice
Author Message
Guest






PostPosted: Wed Jun 13, 2007 8:50 am    Post subject: PC3424 input isolation / use with ADF25A Reply with quote

Considering purchase of a PC3424 for diagnostic work on our electro-mechanical system. For some measurements I will need input isolation (only to ~ 10 - 20V, not mains). The brochure on 3242 suggests that the grounds might be common, but doesn't actually say it explicitly - please can you confirm either way?

Assuming the inputs aren't isolated, we would consider getting an ADF25A (differential input module) - is there any more info please on this beyond the paragraph on the accessories site (URL not permitted Sad )

Thanks,
Richard.

PS - like the new anti-bot tool, not seen it before. Hope it works...
Back to top
ziko
Site Admin
Site Admin


Joined: 01 Dec 2006
Posts: 596
Location: St Neots

PostPosted: Mon Jun 18, 2007 12:34 pm    Post subject: Reply with quote

Hi and thank you for your post.

You are correct the unit is not isolated and the grounds are common.

What information do you require regarding the ADF25A?

Kind regards

Ziko
Back to top