Let us know your exact requirements and we will match them with one of our products. Include details such as (Sampling Rate, Voltage/Current Range, Number of Channels, etc).
by Davy Dick » Thu Dec 14, 2006 12:11 pm
I wish to examine the data stream that is sent to servos.
This requires looking, in real time, at a 1mS to 2mS pulse that occurs once every 20mS.
Can the 2104, the ADC-40 and the ADC-42 all display such a waveform in real time?
-
Davy Dick
-
by davidj » Fri Dec 15, 2006 10:01 am
Hi
The high sampling rate of the 2104 combined with on board buffer memory would be the best choice. You might also consider the 2105 which is currently discounted.
Regards,
David
-
davidj
- Site Admin

-
- Posts: 43
- Joined: Wed Oct 11, 2006 9:50 am
- Location: St. Neots, Cambs, UK