reading servo streams

Let us know your exact requirements and we will match them with one of our products. Include details such as (Sampling Rate, Voltage/Current Range, Number of Channels, etc).

reading servo streams

Postby Davy Dick » Thu Dec 14, 2006 12:11 pm

I wish to examine the data stream that is sent to servos.
This requires looking, in real time, at a 1mS to 2mS pulse that occurs once every 20mS.
Can the 2104, the ADC-40 and the ADC-42 all display such a waveform in real time?
Davy Dick
 

reading servo streams

Postby davidj » Fri Dec 15, 2006 10:01 am

Hi
The high sampling rate of the 2104 combined with on board buffer memory would be the best choice. You might also consider the 2105 which is currently discounted.
Regards,
David
davidj
Site Admin