View unanswered posts | View active topics
|
Page 1 of 1
|
[ 2 posts ] |
|
| Author |
Message |
|
Mikegr
|
Post subject: Voltage/Current Datalogging Posted: Fri Nov 06, 2009 8:38 pm |
|
|
|
|
Need to be able to monitor at least 2 current channels (0-20A) and one voltage channel (0-800Vdc/AC). Witch Pico Device/Attachments with Cal Certs would be best suited for this application?
|
|
| Top |
|
 |
|
PeterF
|
Post subject: Re: Voltage/Current Datalogging Posted: Thu Nov 12, 2009 12:08 pm |
|
 |
| Site Admin |
 |
Joined: Thu Jun 07, 2007 10:53 am Posts: 250 Location: Cambridgeshire
|
|
Hi, You can use two "PP264" 20A/60A AC/DC current clamps for the current and a TA057 active differential probe for the high voltage. We cannot calibrate them ourselves so you will need to have them independently calibrated. You can use a four channel 3424 or 4424, 12 bit scope for which we do offer calibration. PeterF.
|
|
| Top |
|
 |
|
Page 1 of 1
|