Hi,

I have some problems setting the timebase in the adc200.vi example for LabView.

I updated the software for my pico adc212 card using PicoFull_r5_15_6.exe
The set_timebase routine from the adc200.vi exemple has tho following inputs and outputs:
inputs: 0 -for the time interval between readings
0 -for is slow mode
0 - for the timebase

these give me an output of 333 ns, which coresponds to the fastest for an ADC-212/3 (as I found in the pico driver documentation).
The problem is that my real time/sample (it works well with picoscope software) is of the order of microseconds, possibly 333 microseconds (for those input parameters).
My question: Could it be microseconds, instead of ns ?

Regards,
Florin
Back to top
ziko
Site Admin
Site Admin


Joined: 01 Dec 2006
Posts: 586
Location: St Neots

PostPosted: Thu Dec 28, 2006 2:00 pm    Post subject: Reply with quote

Hi and thank you for your post.

Currently we are running a limited service over the Christmas period and as such I cannot answer any programming questions. However we will be operating fully from next week.

Sorry for any inconvenience.

Kind regards
Back to top
Florin
Advanced User
Advanced User


Joined: 09 Oct 2006
Posts: 10
Location: Italy

PostPosted: Thu Dec 28, 2006 2:19 pm    Post subject: solved Reply with quote

Hi,
I solved that problem allready, thanks




ziko wrote:
Hi and thank you for your post.

Currently we are running a limited service over the Christmas period and as such I cannot answer any programming questions. However we will be operating fully from next week.

Sorry for any inconvenience.

Kind regards
Back to top
Display posts from previous:   
Post new topic   Reply to topic    Pico Technology Forum Index -> LabVIEW
All times are GMT
Page 1 of 1

 


Pico Technology topic RSS feed 
Powered by phpBB © 2001, 2005 phpBB Group