electro
User
User


Joined: 27 Jul 2006
Posts: 3
Location: Hants

PostPosted: Thu Jul 27, 2006 10:18 am    Post subject: adc200.vi in LabVIEW 8.0 Reply with quote

I am trying to use adc200.vi (parallel port) in LabView 8.0 on a Windows XP system. Whenever I try to run it comes back with the error message -VI "adc200.vi" was stopped at Call Library Function Node 0x2074 of subVI "adc200.vi"". Can you help me please.
Back to top
Michael
Guru
Guru


Joined: 07 Jul 2005
Posts: 93
Location: St Neots, Cambridgeshire

PostPosted: Mon Jul 31, 2006 11:08 am    Post subject: Reply with quote

Hello,

I have had a look at this VI and found a couple of problems.

Fisrtly, the ADC200_run function was causing a crash as there was a missing returns declaration. Next, there was no ADC200_close function call which was preserving the driver within the LabVIEW development enviroment. The only way to escape this was to restart LabVIEW. I have now added a close function at the end of the stacked sequence.

This should help you out, you will need to register and post a reply to see the attachment in the topic review window.

Best regards,
Michael



adc200.zip
 Description:

Download
 Filename:  adc200.zip
 Filesize:  24.01 KB
 Downloaded:  2397 Time(s)

Back to top
electro
User
User


Joined: 27 Jul 2006
Posts: 3
Location: Hants

PostPosted: Mon Jul 31, 2006 3:22 pm    Post subject: adc200.vi Reply with quote

Thanks I'll try it out
Back to top
electro
User
User


Joined: 27 Jul 2006
Posts: 3
Location: Hants

PostPosted: Mon Jul 31, 2006 3:32 pm    Post subject: adc200.vi Reply with quote

I've registered and sent you a reply but the attachment is eluding me. Am I missing something.
Back to top
Michael
Guru
Guru


Joined: 07 Jul 2005
Posts: 93
Location: St Neots, Cambridgeshire

PostPosted: Tue Aug 01, 2006 9:16 am    Post subject: Reply with quote

Hello,

Go to the post reply section and scroll down. You will see the topic review section and then scroll down to through the messages until you see my message with the attachment.

Best regards,
Michael
Back to top
MEbner
Newbie


Joined: 13 Sep 2006
Posts: 1

PostPosted: Wed Sep 13, 2006 8:57 pm    Post subject: Reply with quote

Hi,

I'm having the same problem with my .vi, however, I have Labview 7.1, and the version posted here is for 8.0. Would it be possible to get the updated .vi in a version compatible with 7.1?

Thanks.
Back to top
Michael
Guru
Guru


Joined: 07 Jul 2005
Posts: 93
Location: St Neots, Cambridgeshire

PostPosted: Wed Oct 11, 2006 10:56 am    Post subject: Reply with quote

Hello,

Please find the VI you requested attached to this post.

Please pst a reply and scroll down through the previous post to see the attached example.

Best regards,
Michael



adc200.vi
 Description:

Download
 Filename:  adc200.vi
 Filesize:  94.7 KB
 Downloaded:  2365 Time(s)

Back to top
RAVI
Active User
Active User


Joined: 05 Dec 2006
Posts: 5

PostPosted: Tue Dec 05, 2006 9:06 pm    Post subject: adc200 Reply with quote

labview 8 attachment
Back to top
mikebettinger
Newbie


Joined: 29 Dec 2006
Posts: 1

PostPosted: Fri Dec 29, 2006 6:39 pm    Post subject: ADC200 labview attachment Reply with quote

How do I get a copy of this file? Thanks, Mike.
Back to top
liurong82
User
User


Joined: 03 Jul 2008
Posts: 2

PostPosted: Thu Jul 03, 2008 12:22 pm    Post subject: Reply with quote

very good!thanks
Back to top
liurong82
User
User


Joined: 03 Jul 2008
Posts: 2

PostPosted: Thu Jul 03, 2008 12:42 pm    Post subject: Reply with quote

why i can't download the atachment!?????