Advice Needed for Audio Amplifier Measurement

 
Post new topic   Reply to topic    Pico Technology Forum Index -> Pre-Sales Advice
Author Message
DonCameron
Guest





PostPosted: Sun Nov 05, 2006 4:23 pm    Post subject: Advice Needed for Audio Amplifier Measurement Reply with quote

We build musical instrument amplifiers. We would like to perform spectral analysis on the signal as it progresses through the amplifier to see where harmonics are injected, etc. Here is roughly the process:

1. Sample instrument signals are fed into the amplifier
2. Signals are recorded in approx 4 places through the amp. Signal levels vary from 100mV to 300V
3. Signals are saved and converted to WAV file format
4. Signals are then post processed using audio spectral analysis software.

And some constraints:
- Signals need to have high sample size to ensure fidelity with analysis software (16bit OK, 24 bit is best)
- Signal aquisition needs to be of high impedance so as to not load amp circuit down


We are currently using BitScope, but it does not have high enough sample size to give us the information we want.

We have also looked at using high end audio interfaces, which have high sample size, but unfortuanately are low-Z input and also require pre-amplifiers.

Can you suggest a product of yours that can help?

thanks
Don
Back to top
DonCameron
Guest





PostPosted: Sun Nov 05, 2006 4:24 pm    Post subject: Reply with quote

I forgot to point out, these are all one-shot events.
Back to top
Michael
Guru
Guru


Joined: 07 Jul 2005
Posts: 93
Location: St Neots, Cambridgeshire

PostPosted: Mon Nov 06, 2006 9:02 am    Post subject: Reply with quote

Hello,

Thank you for your post.

Our current best instrument for this type of application is the ADC216. THis is a 16bit scope designed with audio frequency analysis in mind.

With an input impedance of 1 MΩ, this would sit well in your application.

Further information is available from our website: http://www.picotech.com/audio_spectrum_analyzer.html

Best regards,
Michael
Back to top
Don Cameron
Guest





PostPosted: Mon Nov 06, 2006 2:02 pm    Post subject: Reply with quote

A couple of questions about the ADC216

I see the ADC216 is a parallel port device.

(1) Can you suggest a parallel port to USB converter - we use laptops that do not have parallel ports

(2) What I/O speed does this device run at with a USB converter?

(3) Our one shot sample lebgths are 2 seconds. I expect to record with both channels. With the ADC216 max 2 channel sample rate of 166 kSa/sec and a buffer of 32kSa, 2 secs of data would fill the buffer in under 0.2 seconds. The device would have to stream to the PC to capture the 2 seconds of data, the sample rate would have to be degraded or both. Can you please tell me what happens in this situation?

thanks
Don
Back to top
Michael
Guru
Guru


Joined: 07 Jul 2005
Posts: 93
Location: St Neots, Cambridgeshire

PostPosted: Tue Nov 07, 2006 9:04 am    Post subject: Reply with quote

Hello,

Upon your specification, the ADC216 will not meet your requirements.

You are risght about the buffer and record length, this will not give you 2 seconds.

Even with the USB adapter, you will not get the transfer time required for streaming. Unfortunately, the only instruments we have that comes clos to your specifications is a 12bit scope.
http://www.picotech.com/pc-scope.html

Best regards,
Michael
Back to top
Display posts from previous:   
Post new topic   Reply to topic    Pico Technology Forum Index -> Pre-Sales Advice
All times are GMT
Page 1 of 1

 


Pico Technology topic RSS feed 
Powered by phpBB © 2001, 2005 phpBB Group