R6 Measurements Frequency is not correct

 
Post new topic   Reply to topic    Pico Technology Forum Index -> PicoScope Automotive 6
Author Message
ed800uk
Super User
Super User


Joined: 03 Jul 2006
Posts: 35

PostPosted: Mon Oct 23, 2006 8:50 am    Post subject: R6 Measurements Frequency is not correct Reply with quote

There seem to be several defects in the way that Frequency measurement is reported. The attachments show that Whole trace is incorrectly estimated. Also, (possibly the same poor algorithm) Between rulers continues to give the same estimate, even when the rulers are moved closer together.

I think that there might be problems relating to Cycle at ruler measurements too.
Regards,
Ed
Back to top
Michael
Guru
Guru


Joined: 07 Jul 2005
Posts: 93
Location: St Neots, Cambridgeshire

PostPosted: Mon Oct 23, 2006 10:17 am    Post subject: Reply with quote

Thank you Ed,

Pleas keep your comments coming in.

Best regards,
Michael
Back to top
ed800uk
Super User
Super User


Joined: 03 Jul 2006
Posts: 35

PostPosted: Mon Oct 23, 2006 11:47 pm    Post subject: Reply with quote

Michael,

I can confirm that I am having trouble with the Measurements... Frequency... Cycle at ruler X...

Attached a PDF showing strange value which might be stuck at the mean Frequency of the whole buffer trace, not even changing for each view. Weird.

Actually I think that even when working correctly, the limitation of just two rulers (which is fine for the value axes); for the time axis, it is too restrictive for Automotive. How about a thread for features we'd like to see added?

Best regards,
Ed