ADC-212/100

 
Post new topic   Reply to topic    Pico Technology Forum Index -> Pre-Sales Advice
Author Message
Asim
Guest





PostPosted: Sun Nov 17, 2002 12:27 am    Post subject: ADC-212/100 Reply with quote

Q-1
I want to measure frequency & amplitude of a pulse having width of 13msec and time interval between two pulses is 1.7sec. The frequency of the pulse is 9.5kHz.

Q-2
Can we use ADC-212 to record and analyze the pulse train?

Thanks
Dr. Asim
Back to top
matthew
Site Admin
Site Admin


Joined: 25 Sep 2002
Posts: 133
Location: Cambridgeshire, UK

PostPosted: Mon Nov 18, 2002 10:11 am    Post subject: Repetitive Pulse Trains Reply with quote

Thank you for the post Dr Asim,
I have moved this topic to the Pre-Sales Advice section since this is more appropriate.

The ADC-212/100 will meet your requirements:
The Analogue bandwidth of the ADC-212/100 is 50Mhz (you only need 10kHz).
In order to achieve the 1.7 second interval time we will need to work out the memory buffer's download time. The memory buffer can download at a rate of 60,000 Samples per second. Therefore we can take no more than 1.5 x 60,000 = 90,000 Samples over the 13 ms period (equates to approx. 7M Samples per second).

In short, this will be no problem for the ADC-212/100.

Best Regards,
Back to top
mblaow
Guest





PostPosted: Thu Apr 03, 2003 12:19 pm    Post subject: ADC-216 Reply with quote

Can you please tell me the price of ADC-216 ?
Back to top
matthew
Site Admin
Site Admin


Joined: 25 Sep 2002
Posts: 133
Location: Cambridgeshire, UK

PostPosted: Fri Apr 04, 2003 8:17 am    Post subject: Reply with quote

Hi,

The current price of the ADC-216 is £499GBP excluding tax and delivery.

Best Regards,
Back to top
Display posts from previous:   
Post new topic   Reply to topic    Pico Technology Forum Index -> Pre-Sales Advice
All times are GMT
Page 1 of 1

 


Pico Technology topic RSS feed 
Powered by phpBB © 2001, 2005 phpBB Group