Help: PS3206 no_of_samples vs time_base

 
Post new topic   Reply to topic    Pico Technology Forum Index -> General Software Discussions
Author Message
feng_lin78
Active User
Active User


Joined: 10 Aug 2005
Posts: 7

PostPosted: Tue Jan 31, 2006 5:30 pm    Post subject: Help: PS3206 no_of_samples vs time_base Reply with quote

I modified the Excel macro for PS3206:


Block mode;
Timebase = 10 (5.12us)
Oversamples = 1


How many samples can I work with? i.e. maximum no_of_samples

For PicoLog, it seems I can record over 1 million samples, but excel crashed everytime I set no_of_sample to a few hundreds.

I need a sample rate over 200 KHz and recording time bigger than 5 seconds.

Any suggestions? Exclamation
Back to top
Michael
Guru
Guru


Joined: 07 Jul 2005
Posts: 93
Location: St Neots, Cambridgeshire

PostPosted: Mon Feb 06, 2006 2:33 pm    Post subject: Reply with quote

Hello Feng,

The 3206 has a 1 megasample memory buffer. MS Excel will normally stop at around 65000 rows. MS Access may offer more rows as it is built for handling bigger numbers.

PicoScope is capable of handling data from the 3206. You may find that taking your data from PicoScope is better.

Best regards,
Michael
Back to top
feng_lin78
Active User
Active User


Joined: 10 Aug 2005
Posts: 7

PostPosted: Mon Feb 06, 2006 5:44 pm    Post subject: Reply with quote

Got it working, thanks for the reply!