Humidity

 
Post new topic   Reply to topic    Pico Technology Forum Index -> Pre-Sales Advice
Author Message
GrahamP
Guest





PostPosted: Mon Feb 17, 2003 10:41 am    Post subject: Humidity Reply with quote

I need to record temperature and humidity in an Environmental Cabinet. The cabinet has a Temperature control range of –40 to +150 and a Humidity control from 0 – 95% RH.

Most humidity sensors I have seen are only suitable for temperatures up to 85 deg C. I was thinking of using a Pico Logger and wet and dry thermocouples, but how can I convert them to RH in real time.
Back to top
matthew
Site Admin
Site Admin


Joined: 25 Sep 2002
Posts: 133
Location: Cambridgeshire, UK

PostPosted: Mon Feb 17, 2003 5:34 pm    Post subject: Reply with quote

Hi Graham,

If you are talking, 40 to 150degC then our humidity sensor won't be able to cope with this either.

I can't remember the equations for relative humidity now (its been a while Rolling Eyes). The correct terminology is Wet Bulb Temperature, try typing it into a search engine; I'm sure there will be a fair bit of information available.
Let me know if you find any good info.

Kind Regards,
Back to top
Guest






PostPosted: Tue Feb 18, 2003 8:35 am    Post subject: Reply with quote

Hi Matt

Thanks for that, but what I was trying to find out was is it possible, in the pico log software, to use 2 channels, the dry and wet bulb temperatures, use them both into an equation with the result of an extra derived channel of RH in real time?

regards
Graham
Back to top
matthew
Site Admin
Site Admin


Joined: 25 Sep 2002
Posts: 133
Location: Cambridgeshire, UK

PostPosted: Wed Feb 19, 2003 8:35 am    Post subject: Reply with quote

Yes, no problem ... if you know the equation! Smile

Regards,
Back to top
GrahamP
Guest





PostPosted: Thu Feb 27, 2003 2:55 pm    Post subject: Reply with quote

Hi

Well Mat, never wanting to be out done, and always liking a challenge, here you are. But will it work in PicoLog!!!!

C2 = Dry bulb temperature in Deg C
C3 = Wet bulb temperature in Deg C
Assuming a barometric pressure of 1013 mbar

Relative Humidity =

100*((POWER(2.71828,(((16.78*C3)-116.9)/(C3+237.3)))-(0.00066*((1+(0.00115*C3)))*104*(C2-C3)))/POWER(2.71828,(((16.78*C2)-116.9)/(C2+237.3))))

Thanks to Qwest.net for the formula.

If you put this formula into Excel, you can check the answers at:

http://www.users.qwest.net/~daveoc/demo/wetbulb.htm

Regards
Graham
Back to top
matthew
Site Admin
Site Admin


Joined: 25 Sep 2002
Posts: 133
Location: Cambridgeshire, UK

PostPosted: Fri Feb 28, 2003 11:46 am    Post subject: Reply with quote

Hi Graham,

The equation shouldn't be a problem for PicoLog once you've converted it to our notation (as detailed in our help files).

Best Regards,
Back to top
GrahamP
Guest





PostPosted: Tue Mar 11, 2003 2:09 pm    Post subject: Reply with quote

Hi
Sorry but I used powers instead of exponents in the equation. I have tested this one and it does work

%RH= 100*((EXP(((16.78*C3)-116.9)/(C3+237.3))-(0.00066*((1+(0.00115*C3)))*101.325*EXP(0.0001184*C4)*(C2-C3)))/EXP(((16.78*C2)-116.9)/(C2+237.3)))

Where:
C3 is the wet bulb temperature in degrees centegrade.
C2 is the dry bulb temperature in degrees centegrade.
C4 equal to the height above sea level in metres.
(101.325*EXP(0.0001184*C4) (in red) is the air pressure in kPa. This section can be replaced by the barometric pressure if known.

Regards
Graham
Back to top