| Author |
Message |
mat Newbie
Joined: 18 Nov 2004
Posts: 1
|
Posted: Thu Nov 18, 2004 4:37 pm Post subject: Thermocouple hot junction |
|
|
I am measuring the temperature of a cast iron component. The thermocouple wires are resistance welded to the cast iron. The wires are not touching and there is ~2 mm gap between the wires.
Must the thermocouple wires be touching where the wires are welded to the cast iron? Or, is it acceptable to have a small gap between the wires as described above?
Thanks for any help you can provide. |
|
| Back to top |
|
 |
Martin Guest
|
Posted: Fri Nov 19, 2004 9:23 am Post subject: Thermocouple hot junction |
|
|
| Thermocouple junctions work fine even when joined via a third metal (e.g. solder) - they don't have to be twisted together. The only unwanted effect might be if there is a significant temperature difference across the third metal, which sounds unlikely in your case. |
|